![ABB ACS580-07 Hardware Manual Download Page 65](http://html.mh-extra.com/html/abb/acs580-07/acs580-07_hardware-manual_2985065.webp)
This table shows the requirements when an ABB motor is in use.
Requirement for
Nominal AC supply
voltage
Motor
type
ABB du/dt and common mode filters, insulated N-end
motor bearings
Motor insula-
tion system
P
N
≥ 350 kW
or
frame size ≥ IEC 400
100 kW ≤ P
N
< 350
kW
or
IEC 315 ≤ frame size
< IEC 400
P
N
< 100 kW
and frame
size <
IEC 315
P
N
≥ 469 hp
or
frame size >
NEMA 580
134 hp ≤ P
N
< 469 hp
or
NEMA 500 ≤ frame
size ≤ NEMA 580
P
N
< 134 hp
and frame
size <
NEMA 500
+ N + CMF
+ N
-
Standard
U
N
≤ 500 V
Random-
wound
M2_, M3_
and M4_
+ N + d
u
/d
t
+ CMF
+ N + d
u
/d
t
+ d
u
/d
t
Standard
500 V <
U
N
≤ 600 V
or
+ N + CMF
+ N
-
Reinforced
+ N + d
u
/d
t
+ CMF
+ N + d
u
/d
t
+ d
u
/d
t
Reinforced
600 V <
U
N
≤ 690 V
(cable length ≤
150 m)
+ N + CMF
+ N
-
Reinforced
600 V <
U
N
≤ 690 V
(cable length >
150 m)
P
N
< 500 kW:
+N + CMF
+ N + CMF
n.a.
Standard
380 V <
U
N
≤ 690 V
Form-
wound
HX_ and
AM_
P
N
≥ 500 kW:
+N + d
u
/d
t
+ CMF
+ N + d
u
/d
t
with voltages over 500 V + CMF
Check with the
motor manu-
facturer.
380 V <
U
N
≤ 690 V
Old
1)
form-
wound
HX_ and
modular
+ N + CMF
Enamelled
wire with fiber
glass taping
0 V <
U
N
≤ 500 V
Random-
wound
HX_ and
AM_
2)
+ N + d
u
/d
t
+ CMF
500 V <
U
N
≤ 690 V
Consult the motor manufacturer.
HDP
1) manufactured before 1.1.1998
2) For motors manufactured before 1.1.1998, check for additional instructions with the motor manufacturer.
Guidelines for planning the electrical installation 65
11
Summary of Contents for ACS580-07
Page 1: ... ABB GENERAL PURPOSE DRIVES ACS580 07 Hardware manual ...
Page 2: ......
Page 4: ......
Page 14: ...14 ...
Page 21: ...Measuring points of frames R6 to R9 are shown below PE L1 L2 L3 Safety instructions 21 ...
Page 26: ...26 ...
Page 30: ...30 ...
Page 50: ...50 ...
Page 62: ...62 ...
Page 95: ...Electrical installation 95 11 ...
Page 101: ...Electrical installation 101 11 ...
Page 114: ...114 ...
Page 128: ...128 ...
Page 134: ...134 ...
Page 142: ...142 Maintenance ...
Page 155: ...3 4 5 Maintenance 155 ...
Page 157: ...8 Disconnect the drive module output busbars M12 70 N m 52 lbf ft 7 8 Maintenance 157 ...
Page 161: ...4 5 3 Maintenance 161 ...
Page 163: ...8 Disconnect the drive module output busbars M12 70 N m 52 lbf ft 7 8 Maintenance 163 ...
Page 169: ...1 2 3 5a 5b CR2032 Maintenance 169 ...
Page 170: ...170 ...
Page 186: ...Frame R6 Input and motor cable terminal dimensions option F289 DET A 186 Technical data ...
Page 201: ...Frame R9 Input and motor cable terminal dimensions option F289 Technical data 201 ...
Page 202: ...Frame R10 Input and motor cable terminal dimensions bottom entry and exit 202 Technical data ...
Page 204: ...Frame R10 Input and motor cable terminal dimensions top entry and exit 204 Technical data ...
Page 206: ...Frame R11 Input and motor cable terminal dimensions bottom entry and exit 206 Technical data ...
Page 208: ...Frame R11 Input and motor cable terminal dimensions top entry and exit 208 Technical data ...
Page 217: ...Declaration of Conformity Technical data 217 ...
Page 218: ...218 Technical data ...
Page 223: ...Dimension drawings Example dimension drawings are shown below 13 Dimension drawings 223 ...
Page 224: ...Frames R6 and R7 IP21 UL Type 1 224 Dimension drawings ...
Page 225: ...Frames R6 and R7 B054 IP42 UL Type 1 Dimension drawings 225 ...
Page 226: ...Frames R6 and R7 B055 IP54 UL Type 12 226 Dimension drawings ...
Page 227: ...Frames R6 and R7 H351 and H353 top entry and exit Dimension drawings 227 ...
Page 228: ...Frames R6 and R7 F289 228 Dimension drawings ...
Page 229: ...Frames R6 and R7 F289 H351 H353 Dimension drawings 229 ...
Page 230: ...Frames R8 and R9 IP21 230 Dimension drawings ...
Page 231: ...Frames R8 and R9 B054 IP42 UL Type 1 Dimension drawings 231 ...
Page 232: ...Frames R8 and R9 B055 IP54 UL Type 12 232 Dimension drawings ...
Page 233: ...Frames R8 and R9 H351 and H353 top entry and exit Dimension drawings 233 ...
Page 234: ...Frames R8 and R9 F289 234 Dimension drawings ...
Page 235: ...Frames R8 and R9 F289 H351 H353 Dimension drawings 235 ...
Page 236: ...Frames R10 and R11 IP21 236 Dimension drawings ...
Page 237: ...Frames R10 and R11 B054 IP42 UL Type 1 Dimension drawings 237 ...
Page 238: ...Frames R10 and R11 B055 IP54 UL Type 12 238 Dimension drawings ...
Page 239: ...Frames R10 and R11 F289 T Dimension drawings 239 ...
Page 240: ...Frames R10 and R11 H351 H353 240 Dimension drawings ...
Page 241: ...Frames R10 and R11 B054 IP42 UL type 1 H351 H353 T Dimension drawings 241 ...
Page 242: ...Frames R10 and R11 B055 IP54 UL type 12 H351 H353 T 242 Dimension drawings ...
Page 257: ... Declaration of conformity The Safe torque off function 257 ...
Page 269: ...Setting Parameter 1 s 15 09 RO4 OFF delay Optional I O extension modules 269 ...