Safety instructions 17
Additional instructions and notes
WARNING!
Obey these
instructions. If you ignore them, injury or death, or
damage to the equipment can occur.
•
If you are not a qualified electrician, do not do installation or maintenance work.
•
Do not connect the drive to a voltage higher than what is on the type designation label.
If you do, the brake chopper starts to operate which causes the overheating of the
brake resistor (if present). Overvoltage can also cause the motor to rush to its
maximum speed.
•
We do not recommend that you secure the cabinet by arc welding. If you have to, obey
the instructions in section
on page
•
Do not do insulation or voltage withstand tests on the drive or drive modules.
Note:
•
The motor cable terminals of the drive are at a dangerous voltage when the input
power is on, regardless of whether the motor is running or not.
•
External wiring can supply dangerous voltages to the terminals of relay outputs
(XRO1, XRO2 and XRO3).
•
The Safe torque off function does not remove the voltage from the main and auxiliary
circuits. The function is not effective against deliberate sabotage or misuse.
WARNING!
Use a grounding wrist band when you handle the printed circuit
boards. Do not touch the boards unnecessarily. The boards contain components
sensitive to electrostatic discharge.
WARNING!
Obey these
instructions. If you ignore them, equipment malfunction
and damage to the fiber optic cables can occur.
•
Handle the fiber optic cables with care.
•
When you unplug the cables, always hold the connector, not the cable itself.
•
Do not touch the ends of the fibers with bare hands as the ends are extremely
sensitive to dirt.
•
Do not bend the fiber optic cables too tightly. The minimum allowed bend radius is
35 mm (1.4 in).
Summary of Contents for ACS580-07-0495A-4
Page 1: ...ABB general purpose drives Hardware manual ACS580 07 drives 250 to 500 kW ...
Page 4: ......
Page 8: ...4 Update notice ...
Page 16: ...12 ...
Page 24: ...20 Safety instructions ...
Page 42: ...38 Operation principle and hardware description ...
Page 74: ...70 Electrical installation PE PE 8 PE 13 11 7 8 12 13 ...
Page 82: ...78 Electrical installation ...
Page 102: ...98 Fault tracing ...
Page 114: ...110 Maintenance R10 and R11 4 5 2 7 6 3 8 ...
Page 115: ...Maintenance 111 R10 and R11 9 10 ...
Page 116: ...112 Maintenance R10 and R11 11 ...
Page 117: ...Maintenance 113 R10 and R11 12b 12a ...
Page 118: ...114 Maintenance R10 and R11 R10 and R11 17 14 13 R11 15 16 ...
Page 134: ...130 Technical data ...
Page 137: ...Dimension drawings 133 13 Dimension drawings Example dimension drawings are shown below ...
Page 138: ...134 Dimension drawings Frames R10 and R11 IP42 ...
Page 139: ...Dimension drawings 135 Frames R10 and R11 IP54 option B055 ...
Page 140: ...136 Dimension drawings ...
Page 152: ...148 Safe torque off function ...
Page 174: ...Contact us www abb com drives www abb com drivespartners 3AXD50000032622 Rev A EN 2016 03 16 ...