26
RN Series Feature String Nomenclature
:
S
IZ
E
V
L
T
C
O
N
F
IG
A1
A2
A3
A4
B1
B2
B3
1A
1B
1C
1D
2
3
4
5A
5B
5C
6A
6B
6C
7
8
9
10
11
12
13
14A
14B
15
16
17
18
19
20
21
22
23
2 5
–
3
–
0
–
BB 0 2
–
3 8 4 : A 0 0 0
–
D 0 B
–
DEH
–
0 BA
–
0 D 0 0 0 0 L
–
0 0
–
0 0 B
0 0 0 0 0 B
Model Options
Unit Feature Options
Feature 18: ELECTRICAL RATING
0 = Standard - 5 kAIC
1 = 10 kAIC
2 = 35 kAIC
3 = 65 kAIC
Feature 19: CODE OPTIONS
0 = Standard - ETL U.S.A. Listing
B = Chicago - Cool + Gas
C = Chicago - Cool + Electric Heat
D = Chicago - Cool Only
E = Chicago - Gas Only
F = Chicago - Electric Heat Only
G = Chicago - No Cool + No Heat
H = ETL U.S.A. + Canada Listing
K = California OSHPD Certification
L = Shake Table Cert. (ASCE 7-05/ICC-ES AC 156)
M = Seismic Construction (Non-Certified)
N = California OSHPD Certifi Chicago
P = Shake Table Cert. (ASCE 7-05/ICC-ES AC 156)
+ Chicago
Q = Seismic Construction (Non-Certified) + Chicago
Feature 20: CRATING
0 = Standard
A = Export Crating
B = Export Crating - No Condenser Section
C = Shrink Wrap
D = Options A + C
E = Options B + C
Feature 21: WATER-COOLED
CONDENSER
0 = Standard - None
A = Balancing Valves
B = Water Flow Switch
C = Motorized Shut-off Valve
D = Head Pressure Control Valve
E = Options A + B
F = Options A + C
G = Options A + D
H = Options B + C
J = Options B + D
L = Options A + B + C
M = Options A + B + D
Feature 22: CONTROL VENDORS
0 = None
T = VCB-X Controls Integrated BACnet
MSTP
U = VCB-X Controls Integrated BACnet
MSTP with Specials
V = VCC-X Controls Integrated BACnet
MSTP
W = VCC-X Controls Integrated BACnet
MSTP with Specials
Y = Remote Mounted AAON Touchscreen
Controller
Z = VCC-X w/BACnet MSTP & Split System
1 = VCC-X w/BACnet MSTP w/Specials & Split
System
Feature 23: TYPE
B = Standard - AAON Gray Paint
U = Special Pricing Authori Special Paint
X = Special Pricing Authori AAON Gray
Paint
1 = Standard Paint + 2 Year Parts Only Warranty
(Begins at Date of Shipment)
4 = Standard Paint + 5 Year Parts Only Warranty
(Begins at Date of Shipment)
9 = Standard Paint + 10 Year Parts Only Warranty
(Begins at Date of Shipment)
Summary of Contents for RN Series
Page 2: ......
Page 32: ...32 Figure 5 RN Series 6 8 and 10 ton Unit Isolator Locations ...
Page 33: ...33 Figure 6 RN Series 9 and 11 15 ton Unit Isolator Locations ...
Page 34: ...34 Figure 7 RN Series 16 25 and 30 ton Unit Isolator Locations ...
Page 35: ...35 Figure 8 RN Series 26 31 50 60 and 70 ton Unit Isolator Locations ...
Page 36: ...36 Figure 9 Steel Mounting ...
Page 102: ...102 Figure 56 Example 6 50 60 70 ton through the Base Gas Piping ...
Page 105: ...105 Gas Heater Operating Instructions Figure 58 Gas Heater Instructions ...
Page 129: ...Maintenance Log E Coated Coil ...