RN Series Feature String Nomenclature
:
S
IZ
E
V
L
T
C
O
N
F
IG
A1
A2
A3
A4
B1
B2
B3
1A
1B
1C
1D
2
3
4
5A
5B
5C
6A
6B
6C
7
8
9
10
11
12
13
14A
14B
15
16
17
18
19
20
21
22
23
RN
–
0 2 5
–
3
–
0
–
BB 0 2
–
3 8 4 : A 0 0 0
–
D 0 B
–
DEH
–
0 BA
–
0 D 0 0 0 0 L
–
0 0
–
0 0 B
0 0 0 0 0 B
G
E
N
Model Options
Unit Feature Options
Feature 14: PREHEAT
14A: OUTSIDE AIR CONFIGURATION
0 = Standard - None
A = Steam Distributing Preheat Coil - 1 Row
B = Steam Distributing Preheat Coil - 2 Row
C = Hot Water Preheat Coil - 1 Row
D = Hot Water Preheat Coil - 2 Row
E = Modulating Electric Preheat
F = Outside Airflow Monitoring Size A
G = Outside Airflow Monitoring Size B
H = Outside Airflow Monitoring Size C
J = Outside Airflow Monitoring Size D
14B: PREHEAT SIZING
0 = Standard - None
A = Single Serpentine 8 fpi
B = Half Serpentine 8 fpi
C = Single Serpentine 10 fpi
D = Half Serpentine 10 fpi
E = Single Serpentine 12 fpi
F = Half Serpentine 12 fpi
G = 10 kW (7.5 kW @ 208V)
H = 15 kW (11.3 kW @ 208V)
J = 20 kW (15 kW @208V)
K = 30 kW (22.5 kW @208V)
L = 40 kW (30 kW @208V)
M = 50 kW (37.6 kW @208V)
N = 60 kW (45.1 kW @208V)
P = 70 kW (52.6 kW @208V)
Q = 80 kW (60.1 kW @208V)
R = 90 kW (67.6 kW @208V)
S = 100 kW (75.1 kW @208V)
T = 110 kW (82.6 kW @208V)
U = 120 kW (90.1 kW @208V)
Feature 15: GLYCOL PERCENTAGE
0 = Standard - Water or No WSHP with Polymer
Energy Recovery Wheel
C = Field Adjustable for Glycol %
D = Water or No WSHP with Aluminum Energy
Recovery Wheel
Feature 16: INTERIOR CABINET
OPTIONS
0 = Standard
B = Control Panel Service Lights
H = UV Lights
J = Compressor Sound Blanket (CSB)
K = Control Panel Service UV Lights
L = Control Panel Service CSB
M = UV CSB
N = Control Panel Service UV
CSB
Feature 17: EXTERIOR CABINET
OPTIONS
0 = Standard
A = Base Insulation
B = Burglar Bars
C = Condenser Coil Guards (or Screen)
D = Options A + B
E = Options A + C
F = Options B + C
G = Options A + B + C
H = Motorized Relief Dampers
J = Options A + H
K = Options B + H
L = Options C + H
M = Options A + B + H
N = Options A + C + H
P = Options B + C + H
Q = Options A + B + C + H
Summary of Contents for RN Series
Page 2: ......
Page 32: ...32 Figure 5 RN Series 6 8 and 10 ton Unit Isolator Locations ...
Page 33: ...33 Figure 6 RN Series 9 and 11 15 ton Unit Isolator Locations ...
Page 34: ...34 Figure 7 RN Series 16 25 and 30 ton Unit Isolator Locations ...
Page 35: ...35 Figure 8 RN Series 26 31 50 60 and 70 ton Unit Isolator Locations ...
Page 36: ...36 Figure 9 Steel Mounting ...
Page 102: ...102 Figure 56 Example 6 50 60 70 ton through the Base Gas Piping ...
Page 105: ...105 Gas Heater Operating Instructions Figure 58 Gas Heater Instructions ...
Page 129: ...Maintenance Log E Coated Coil ...