January 2014 - TD 302 Operating Manual for Pressure 4117/4117R Tide 5217/5217R, Wave & Tide 5218/5218RPage 21
2.3
Status codes
Status codes indicate the status of parameters and properties, refer Table 2-2 and Table 2-3 .
Table 2-2 Status code common
Table 2-3 Status code parameter warning
Each data set has a common status code. If the common status code is Parameter warning (18), then one or
more of the parameters will have a Parameter Warning status code.
In RS-232, RS-422 and Polled operation errors and warnings will be indicated with a * in front of the parameter
name when the property
Enable Text
is enabled.
In AiCaP mode, the Status Codes will be collected by the
SeaGuard Platform or SmartGuard and can be
presented in SeaGuard Studio or Data Studio. The status codes will be shown in the
Status
column under the
Data List tag. Recordings containing warnings are marked with blue text. Recordings containing errors are
marked with red text. The status field will have a
Common
status code. The
Common
status code indicates
whether there exist problems within the data set. By right clicking the
Status
field, details and the status codes
for each parameter will be shown.
In addition to the listed status codes from the sensor, the SeaGuard platform and SmartGuard logs status codes
for communication errors.
Error, corrupt configuration (3) indicates internal flash error. Parts of the sensor configuration are lost. Contact
AADI Service department for new setting file for the specific sensor with further instructions.
StatusCode (Common)
Number
Description
OK
0
All data OK.
Error, corrupt configuration 3
Internal storage of settings is corrupt.
Warning, watchdog
detected
16
Reset generated by software
Warning, reset detected
17
Reset generated by reset command or power loss/low voltage
Parameter warning
18
Data set contains parameter(s) that is not reliable
StatusCode (Parameter Warning)
Number
Description
Warning, reduced quality
83
Warning, not ready
84
e.g. too few samples to perform calculation