42
SJ-WP Series Class III Model Specifications
MODEL
SJ-3000WP/-BT
SJ-6000WP/-BT SJ-15KWP/-BT SJ-30KWP/-BT
Accuracy class
III
Maximum Capacity
3000 g
6000 g
15 kg
30 kg
Readability
0.5 g(0~1500 g)
1 g(1500~3000 g)
1 g(0~3000 g)
2 g(3000~6000 g)
2 g(0~6 kg)
5 g(6~15 kg)
5 g(0~15 kg)
10 g(15~30 kg)
Minimum capacity
10 g
20 g
40 g
100 g
Maximum tare
3000 g
6000 g
15 kg
30 kg
Operating temp.
-10°C~40°C (No condensation)
Display
Weight display: 7 segment liquid crystal display with White Backlight
Character height: 26mm
Comparator LEDs: red / yellow / green / yellow / red
Display update
Approximately 20 times per second
Power
6 x R20P / LR20 / “D” size batteries
Battery life
(Approximately)
SJ-WP Model
5000 hours with alkaline cells at 20°C (LED & Backlight off )
2000 hours with manganese cells at 20°C (LED & Backlight off )
Battery life
(Approximately)
SJ-WP-BT Model
2500 hours with alkaline cells at 20°C (LED & Backlight off )
1300 hours with manganese cells at 20°C (LED & Backlight off )
Platform size
232 (W) x 192 (D) mm
Dimensions
236
(W) x 260 (D) x 148 (H) mm
Weight
Approximately 4 kg
Calibration weight
3000 g ± 0.1 g
6000 g ± 0.2 g
15 kg ± 0.5 g
30 kg ± 1 g
Note:
The range for power-on zero is within ± 10% of the weighing capacity at the calibrated zero point.
The weighing units “g”, “kg” and “pcs” are available.
The selection in the function settings
re5o
,
at
,
at-t
, and
at-f
is not available.
Power-on:
Turning the power on, the scale will be automatically set to zero.
If the power is switched on with a load /-10 % of the weighing capacity at the calibrated zero point
(power-on zero range), the scale is zeroed and the ZERO indicator turns on.
If the load is beyond the power-on zero range, the scale is tared and the ZERO and the NET indicators
turn on.
Error Message:
-e
: Indicates that the gross value (weight value with no tare operation) is less than -19d. If the
STABLE indicator is ON, press the
switch to ZERO the scale. If the STABLE indicator
is OFF, turn the power off and on again.
If these instructions do not work, there is a possibility that the weight sensor or internal circuit may
have a problem.
Summary of Contents for SJ-15KWP
Page 1: ...SJ 3000WP BT SJ 6000WP BT SJ 15KWP BT SJ 30KWP BT 1WMPD4003567B ...
Page 18: ...16 Lower limit Upper limit ...
Page 46: ...44 World map ...
Page 47: ......