![A.O. Smith SGS - 100 Installation & Service Manual Download Page 46](http://html2.mh-extra.com/html/a-o-smith/sgs-100/sgs-100_installation-and-service-manual_4691891046.webp)
Conversion to a different gas category
46
Instruction manual SGS
4
is
5. Detach the 3-part gas coupling (2) adjacent to the burner.
6. Select and fit the correct orifice from the conversion kit, based on the gas
table
(3.4.3 "Gas data")
. The injector diameter is stamped into each injector
(6).
7. Refit the 3-part gas coupling (2).
8. Check the burner pressure and supply pressure
(3.13 "Checking the supply
pressure and burner pressure")
.
9. Replace the cover.
10. Remove the sticker showing the new gas category from the conversion kit,
and attach it below the appliance's rating plate. This clearly indicates that the
appliance may no longer be run on the gas for which it was originally
supplied.
11. Start
(9 "Starting and running")
the appliance.
Summary of Contents for SGS - 100
Page 1: ...80 100 Installation User and Service Manual Installation User and Service Manual...
Page 2: ...www aosmithinternational com your installer...
Page 4: ...4 Instruction manual SGS gis...
Page 8: ...Table of contents 8 Instruction manual SGS...
Page 12: ...Introduction 12 Instruction manual SGS 1 gis...
Page 44: ...Installation 44 Instruction manual SGS 3 is...
Page 62: ...Shutting down 62 Instruction manual SGS 10 gis...
Page 92: ...Maintenance frequency 92 Instruction manual SGS 14 is...
Page 101: ...Instruction manual SGS 101 is...
Page 106: ...Appendices 106 Instruction manual SGS 17 is...