3.3.4
Appliance working clearances
For access to the appliance, it is recommended that the following clearances
are observed:
•
AA: around the appliance's control column and cleaning openings: 100 cm.
•
BB: all sides of the appliance: 50 cm
•
Above the appliance (room to replace the anodes):
-
100 cm if using rigid anode(s), or
-
50 cm if using flexible anode(s).
If the available clearance is less than 100 cm, flexible magnesium anodes
can be ordered.
Note
When installing the appliance, be aware that any leakage may cause
damage to the immediate environment or floors below the level of the boiler
room. If this is the case, then the appliance should be installed above a
wastewater drain or in a suitable metal leak tray.
3.3.5
Storage tank working clearances
For access to the storage tank, it is recommended that the following
clearances are observed:
•
All sides of the storage tank: 50 cm.
•
Above the storage tank (room to replace the anodes): 100 cm.
Note
When installing the storage tank, be aware that any leakage can cause
damage to the immediate environment or floors below the level of the boiler
room. If this is the case, then the appliance should be installed above a
wastewater drain or in a suitable metal leak tray.
Working clearances
BB
A
A
AA
IMD-0227 R2
Summary of Contents for SGS - 100
Page 1: ...80 100 Installation User and Service Manual Installation User and Service Manual...
Page 2: ...www aosmithinternational com your installer...
Page 4: ...4 Instruction manual SGS gis...
Page 8: ...Table of contents 8 Instruction manual SGS...
Page 12: ...Introduction 12 Instruction manual SGS 1 gis...
Page 44: ...Installation 44 Instruction manual SGS 3 is...
Page 62: ...Shutting down 62 Instruction manual SGS 10 gis...
Page 92: ...Maintenance frequency 92 Instruction manual SGS 14 is...
Page 101: ...Instruction manual SGS 101 is...
Page 106: ...Appendices 106 Instruction manual SGS 17 is...