13
Appendices
13.1
Technical details
Description
Unit
IR-12-160
IR-20-160
IR-12-200
IR-20-200
IR-24-245
IR-32-245
IR-24-285
IR-32-285
IR-32-380
General
Capacity
l
160
200
245
285
380
Empty Weight
kg
95
106
120
136
155
Maximum floor load
kg
255
306
365
421
535
Maximum operating pressure
- installation
kPa (bar)
550 (5.5)
550 (5.5)
550 (5.5)
550 (5.5)
550 (5.5)
Maximum operating pressure
- tank
kPa (bar)
800 (8)
800 (8)
800 (8)
800 (8)
800 (8)
Control thermostat -
adjustment range
°C
40…85
40…85
40…85
40…85
40…85
Control thermostat -
default
value
°C
65
65
65
65
65
Hysteresis upwards -
adjustment range
°C
2…15
2…15
2…15
2…15
2…15
Hysteresis upwards -
default
value
°C
10
10
10
10
10
Number of (electrical) anodes -
1
1
2
2
2
Minimum measured air
pressure differential across
the pressure switch
Pa
≥ 210
≥ 210
≥ 460
≥ 460
≥ 460
Setpoint pressure switch
Pa
175
175
400
400
400
Heating time ΔT = 45 °C
min.
28
(12-160)
18
(20-160)
43
(12-200)
28
(20-200)
26
(24-245)
20
(32-245)
33
(24-285)
25
(32-285)
32
Electrical
Electrical power consumption
(peak)
W
85
85
105
105
105
Electrical power consumption
(nominal)
W
25
(12-160)
36
(20-160)
25
(12-200)
36
(20-200)
51
(24-245)
85
(32-245)
51
(24-285)
85
(32-285)
85
Supply voltage/Main
frequency
VAC / Hz
230 (-15%, +10%) / 50 (± 1)
IP-class
-
IP20
0312266_INNOVO_UKUK_
V5.1, 2022-07-12
81
Summary of Contents for Innovo IR 12-160
Page 6: ...6 ...
Page 13: ...User part 0312266_INNOVO_UKUK_V5 1 2022 07 12 13 ...
Page 14: ...14 ...
Page 16: ...16 User part ...
Page 18: ...18 User part ...
Page 24: ...24 User part ...
Page 27: ...Installation Maintenance and Service part 0312266_INNOVO_UKUK_V5 1 2022 07 12 27 ...
Page 28: ...28 User part ...
Page 36: ...36 Installation Maintenance and Service part ...
Page 56: ...56 Installation Maintenance and Service part ...
Page 58: ...58 Installation Maintenance and Service part ...
Page 70: ...70 Installation Maintenance and Service part ...
Page 83: ...0312266_INNOVO_UKUK_V5 1 2022 07 12 83 ...
Page 87: ...13 4 Electrical wiring diagram 0312266_INNOVO_UKUK_V5 1 2022 07 12 87 ...
Page 89: ...13 5 Declaration of conformity 0312266_INNOVO_UKUK_V5 1 2022 07 12 89 ...
Page 90: ......
Page 91: ......
Page 94: ...92 Installation Maintenance and Service part ...