DIRECTION INDICATORS FLASHING ON THE SYSTEM ACTIVATION /
DESACTIVATION
ACOUSTIC SIGNALINGS ON ACTIVATION / DESACTIVATION
OUT OF ORDER OF THE SYSTEM
BUTTONS INPUT DESACTIVATING
DOORS LOCKING / UNLOCKING TIME - COMFORT
ALARM OUTPUT
RESETTING OF THE INITIAL CONDITIONS PROGRAMMED AT DEFAULT
MAINTENANCE
WARRANTY CONDITIONS
If the opening/closing doors is not signalised by the direction indicators, it's possible to activate
this function by the central unit.
It is possible to cut them out by using the programming keeping the service signalings working
(for example the alarm memory).
Suggested in case the vehicle has to stay in the repair shop, garage, or when the vehicle does
not need to be protected.
When OUT OF ORDER, the system cannot be activated and any attempt gives 5 BEEPS and 5
LED flashings. It cuts out all the central unit functions.
Repeat the programming to activate the system completely again.
It allows to desactivate the doors, bonnet and boot buttons and the additional module detection
(infra red, high frequency sensors, anti lifting etc.), keeping the other protections (starting and
volumetric radar sensor) active.
The standard preset times are
.
With vehicles having a “comfort” equipment (simultaneous windows closing by turning the
original key in the door lock block), it is possible “to automate” the windows closing on the
system activation delaying the doors locking time or using the status output as timed, according
to the vehicle's features.
If necessary, it is possible to let the controls of the doors locking and of the windows closing be
simultaneous, and to preset the opening / closing times at 3 seconds (for example, vehicles
equipped with pneumatic system like MERCEDES W 124 - W 129 series).
With vehicles equipped with security lock activated by the double control on the doors locking
wire, this function can generally be activated.
On the system activation the input can be instantaneous or delayed (30 or 50 seconds then it
becomes instantaneous). It must be delayed when the signal is taken by the delayed switching
off internal roof lamp or if are used the additional modules (anti lifting, high frequency, infra red
etc). The set up depends on the vehicle model and on the paired accessories)
It has to be kept intermittent only if it's used to control the vehicle klaxon otherwise fix in case of
an additional siren or if it's paired to the satellite protection.
It allows to restore the original condition of the central unit, resetting all the default
programmings.
The central unit does not need any maintenance.
The technical warranty has a duration of 24 months from the date of installation, ex-works, and
covers those parts considered as defective only by A.E.B. S.p.A.
Any other external labor or extra costs are excluded.
To use only in case one button or one additional sensor is broken waiting for their repair.
0,8 seconds
WARNING: When washing the engine, protect SIR 050 / SIR 050.NA adeguately.
INSTANTANEOUS / DELAIED BUTTONS INPUT