22
8.16 Movable Cutter Blade
To Remove:
1. Remove Cutter Guard.
2. Remove right side cover
(See Section 8.11).
3. Remove cutter guard clips.
4. Loosen set screw to release tension from blade
(
Figures 8-19).
5. With one hand pushing down on the handle
(
Figures 8-20),
remove two (2) remaining
screws and lift moveable cutter blade out of
dispenser.
Important:
Place a pencil or screw driver under the
blade so that the it doesn't fall into the dispenser.
6. With one hand holding new moveable cutter
blade, place new blade so two (2) outside screw
holes line up. Screw blade into place.
7. Tighten set screw so that there is a slight bend
in the movable cutter blade.
New Part Installation:
Reverse the removal procedure above.
8.17 Fixed Blade
To Remove:
1. Loosen screw retaining the
fi
xed blade stop
and remove stop.
2.
Remove
fi
xed blade retaining screw.
3.
Push
fi
xed blade shoe toward rear of dispenser
(
Figures 8-21).
4. Use a magnet, pull
fi
xed blade from dispenser.
(
Figures 8-22).
5. Insert new
fi
xed blade into chassis.
Important:
The blade should be resting on both
sides of the chassis.
Caution:
Do not drop any components into the
dispenser.
7. Release the
fi
xed blade shoe.
8. Reinstall the
fi
xed blade retaining screw.
9.
Reinstall
fi
xed blade stop and tighten
retaining screw.
Figure 8-19
Figure 8-20
2011 October
WaterAct-M-S
8-MAINTENANCE AND REPAIRS
(continued)
Figure 8-21
Figure 8-22
•
To reduce the risk associated with
sharp blade hazards:
−
Keep hands and
fi
ngers away from
tape cutoff blades. The blades are
extremely
sharp.
CAUTION