86
Additional options
Reverberation results
Models SE and DL
Tabular RT60 screen
This is a table-formatted screen which details a summary of the Reverb Decay
Curve of each band. The following table is a brief summary of the tabular data.
Table 6-2: Tabular RT60 field explanation
Figure 6-7: Tabular octave filtering RT screen
NOTE: if “---”dashes appear, this indicates the measurement values are
invalid.
Viewing Tabulation RT60 screen
1. To view all of the octave band filters, press the
Up/Down
Arrow
keys to
page through the filters’ data results.
Column
Explanation of data
Freq
The Frequency column displays the chosen filter bands (for 1/1 Octave the
range is 63Hz – 8KHz and for 1/3 Octave the range is 50Hz – 10KHz).
T60
T60 column displays the results of the decay curve in seconds.
R
2
R
2
column displays the reverberation time measurements. The values
represent a “goodness to fit” ranging between 0 to 1 values, where 0 = failed
and 1 = perfect.
Txx
Txx column displays the actual measurements of the RT60s’ values.
Summary of the Reverb
Decay curve results for each
octave band.
NOTE: The Txx value may show
different ranges when “Auto” is
selected for the trigger mode.
Summary of Contents for SP-DL-1
Page 1: ...3M Personal Safety Division 3MTM SoundPro SE DL SeriesSound Level Meters SoundProUser Manual ...
Page 13: ...xii Table of Contents Models SE and DL This page left blank intentionally ...
Page 35: ...22 Turning off Navigating Models SE and DL This page left blank intentionally ...
Page 69: ...56 Communications GPS Models SE and DL This page left blank intentionally ...
Page 89: ...76 Back erasing Stopping a session Models SE and DL This page left blank intentionally ...
Page 137: ...AC DC output DC output 124 Models SE and DL This page left blank intentionally ...
Page 149: ...Appendix A 136 Models SE and DL Block Diagram for SoundPro ...
Page 161: ...Appendix B 148 Models SE and DL This page left blank intentionally ...