Downloaded from Projector.com
3M IPC 2000
3M
Multimedia Projector MP8760
15
ENGLISH
5-2. Meaning Of The Icons, continued
Question mark
A question mark in a box will appear if the projector can’t recognize
the mode of the data input source.
Even if you select a standard VESA mode on your system this can happen, because some device drivers of the graphic
cards in the PC using timing parameters which differ from the parameters given out from the VESA organization.
As a result of this, the projector may detects a wrong predefined data mode or switches to a User mode, so you may
see only a part of the whole picture.
To correct this situation you must select manually a data Mode in the Picture menu which should match the mode
you’ve selected on the PC. If there is no matching mode you must select a User mode.
In a User mode you can manually select the Resolution which is normally not choosable.
It may be necessary to correct the
Hor
izontal and
Vert
ical
Position
and the
Tracking
and
Sync
values in the Picture
menu. These values will be stored so the mode can be recognized the next time.
If you’ve accidently misadjusted the values of a standard predefined data mode, you can reset them by selecting Reset
Data Modes in the
Advanced Setup
menu. The settings of a User mode won’t be affected by this action.
Optimize
The image optimize process ist just in progress – please wait a few seconds!
Looking for signal source...
The projector can not find any input signal on the video and data inputs.
Either there is no input source connected to the projector or the source is giving no output signal.
For RGB/PC input sources you must manually select another
Sync Mode
recognition in the
Advanced Setup
menu.