SAFETY INFORMATION
EXPLANATION OF SIGNAL WORD CONSEQUENCES
Read, understand, and follow all safety information contained in these instructions prior to
installation and use of the APIL3 Filtration System. Retain these instructions for future refer-
ence.
Intended use:
The APIL3 Filtration System is intended for use in fi ltering potable water for refrigerators and ice makers and has
not been evaluated for other uses. These systems must be installed as shown in the installation diagrams.
C
CAUTION
WARNING
Indicates a potentially hazardous situation, which, if not avoided, could result in
death or serious injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided, may result in
minor or moderate injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided, may result in
property damage.
CAUTION
WARNING
To reduce the risk associated with choking:
•
Do not
allow children under 3 years of age to have access to small parts during the installation of this product.
To reduce the risk associated with ingestion of contaminants:
•
Do not
use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after
the system.
To reduce the risk associated with a hazardous voltage due to an installer drilling through existing electric wiring or
water pipes in the area of installation:
•
Do not
install near electric wiring or piping which may be in the path of a drilling tool when selecting the position to
mount the fi lter bracket.
CAUTION
To reduce the risk associated with property damage due to water leakage:
•
Read and follow
Use Instructions before installation and use of this system.
• Installation and Use
MUST
comply with all state and local plumbing codes.
•
Protect from freezing
, remove fi lter cartridge when temperatures are expected to drop below 40°F (4.4°C).
•
Do not install
on hot water supply lines. The maximum operating water temperature of this fi lter system is 100˚F (37.8˚C).
•
Do not install
if water pressure exceeds 125 psi (862 kPa). If your water pressure exceeds 80 psi (552 kPa), you must
install a pressure limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure.
• Where a backfl ow prevention device is installed on a water system, a device for controlling pressure due to thermal
expansion must be installed.
•
Do not install
where water hammer conditions may occur. If water hammer conditions exist you must install a water
hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition.
•
Do not
use a torch or other high temperature sources near fi lter system, cartridges, plastic fi ttings or plastic plumbing.
• On plastic fi ttings, never use pipe sealant or pipe dope. Use PTFE thread tape
only
, pipe dope properties may deteriorate
plastic.
•
Do not
install in direct sunlight or outdoors.
•
Do not
install near water pipes which will be in path of a drilling tool when selecting the position to mount the bracket.
• Mount
fi lter in such a position as to prevent it from being struck by other items used in the area of installation.
• Ensure that the location and fasteners will support the weight of the system.
• Ensure all tubing and fi ttings are secure and free of leaks.
• The disposable fi lter cartridge MUST be replaced every 6 months, at the rated capacity or sooner if a noticeable
reduction in fl ow rate occurs.
IMPORTANT NOTES
• Failure to follow instructions will void warranty.
• Install with the inlet and outlet ports as labeled. Make sure not to reverse connections.
Model
Flow Rate
Rated Capacity
Pressure
Temperature
APIL3R
0.5 gpm
(1.9 lpm)
6 months
20-125 psi
(138-862 kPa)
40-100°F
(4.4-37.8°C)