REPLACEMENT PARTS

The following parts are user-replaceable parts:

Description 

Part Number

Model 701 Megohmmeter

3M 701-M, 98-0798-2290-8

Test Weight (each) 

3M 701-W, 98-0798-2291-6

Test Leads (pair) 

3M 701-L, 98-0798-2292-4

Carrying Case 

3M 701-C, 98-0798-2293-2

Insulated “Bulldog” Clip 

3M 3037, 98-0798-0838-6

Noninsulated Alligator Clip 

3M 3038,98-0798-0399-9

Operator’s Manual 

34-7051-4709-7

Batteries (2) 

1.5 volt AA Cell, 22.5 volt 

Eveready 505 (or equivalent*)

*The following are equivalent replacements or alternative sources for the Eveready 505 22.5V battery: NEDA 221, 

Radio Shack 23-510, Newark Electronics (catalog) 49F1064.

6

TECHNICAL DATA

The following electrical specifications are valid for operating temperatures of 65°F (18°C) to 82°F (28°C), at relative
humidity up to 90% for altitudes up to 2000m, unless otherwise noted.  Pollution degree 2, class 3 equipment.

Resistance Ranges

Test

Measurement

Open Circuit

Internal

Function Range*

Voltage**

Resistance

Continuity

0 to 10 M

10V ± .7V

500 

10V Surface

10

5

to 10

11

10V ± .7V

100V Surface

10

5

to 10

11

100V ± .7V

*Measurement Accuracy: ±5%±2° of arc.
**Measured internally at voltage source.

Battery Test

Internal test of 100V source – Accuracy: ± 2% ± 2° of arc

Batteries

1–1.5V AA Cell

1

22.5v Type 505 (Eveready 505)*

*(See replacement parts above for batteries equivalent to the Eveready 505.)

Physical Data

Instrument

Test Weights(2) 

4.6”(H) x 3.3”(W) x 1.8”(D)

Weight: 5 lbs. (2.27 Kg) each

(11,7 x 8,4 x 4,6 cm)

Diameter: 2.5” (6,4 cm)
Height: 4.7” (11.9 cm)

Weight: 12 oz (340 gms)

(w/handle and pad)

Handling and Safety Precautions

Read all Health Hazard, Precautionary, and First Aid statements found in Material Safety Data Sheet (MSDS) and/or
product label of chemicals prior to handling or use.

Summary of Contents for 701

Page 1: ...Operator s Manual 701 Test Kit for Static Control Surfaces Megohmmeter...

Page 2: ...either of two test voltages verify proper Instrument performance and check the electrical continuity of the test set up ACCESSORIES All accessories required for operating the Model 701 are included in...

Page 3: ...nds and then read the resistance from the OHMS scale After all readings have been completed return the Main Selector Switch to the OFF position RESISTIVE CHARACTERIZATION OF STATIC CONTROL WORK SURFAC...

Page 4: ...ngs are above 1x109 ohms the static control surface may be dirty Clean the surface using the manufacturer s recommended cleaning procedure followed by two clear water rinses and a rinse with 70 Isopro...

Page 5: ...building ground or other suitable ground If you have questions concerning the correct ground refer to EOS ESD Standard 6 0 and or contact a qualified electrician The Resistance to Ground test is the m...

Page 6: ...f five tests per 5 000 square feet 464 5 m2 of floor material whichever is greater A minimum of three of the five tests should be conducted in those areas that are subject to wear or have chemical or...

Page 7: ...ative humidity up to 90 for altitudes up to 2000m unless otherwise noted Pollution degree 2 class 3 equipment Resistance Ranges Test Measurement Open Circuit Internal Function Range Voltage Resistance...

Page 8: ...rohibited by law 3M will not be liable for any loss or damage arising from this 3M product whether direct indirect special incidental or consequential regardless of the legal theory asserted Shipping...

Reviews: