background image

Electronic and Interconnect Solutions Division

6801 River Place Blvd.
Austin, TX 78726-9000

© 3M 2003 78-8132-1177-4

Important Notice

Before using this product, you must evaluate it and
determine if it is suitable for your intended application. You
assume all risks and liability associated with such use.

Warranty; Limited Remedy; Limited Liability.

This product will be free from defects in material and
manufacture for a period of 1 year from the date of
purchase. 

3M MAKES NO OTHER WARRANTIES

INCLUDING, BUT NOT LIMITED TO, ANY
IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.

If this

product is defective within the warranty period stated above,
your exclusive remedy shall be, at 3M’s option, to replace or
repair the 3M product or refund the purchase price of the
3M product.

Except where prohibited by law, 3M

will not be liable for any loss or damage arising
from this 3M product, whether direct, indirect,
special, incidental or consequential regardless
of the legal theory asserted.

Shipping of Warranty Returns

Pack the Instrument carefully and ship it prepaid and insured
to the proper destination noted below: 
DO NOT RETURN ANY ITEM WITHOUT HAVING
FIRST RECEIVED RETURN AUTHORIZATION FROM
3M THROUGH YOUR 3M SALES REPRESENTATIVE.

3M
Electronic and Interconnect Solutions Division 
Quality Department
6801 Riverplace Boulevard
Austin, TX 78726 - 4599

Shipping of Nonwarranty returns

Contact 3M Service Repair Center at 800/426-8688 and
select option #2 for the Service and Repair Center.

When calling, please have the following information
available:

• Purchase Order Number

• Name and phone number of an individual who can be

contacted for additional information

• Complete return address

• Description of the problem

You will be given complete instructions, including a RMA
number for returning the instrument.

Summary of Contents for 701

Page 1: ...Operator s Manual 701 Test Kit for Static Control Surfaces Megohmmeter...

Page 2: ...either of two test voltages verify proper Instrument performance and check the electrical continuity of the test set up ACCESSORIES All accessories required for operating the Model 701 are included in...

Page 3: ...nds and then read the resistance from the OHMS scale After all readings have been completed return the Main Selector Switch to the OFF position RESISTIVE CHARACTERIZATION OF STATIC CONTROL WORK SURFAC...

Page 4: ...ngs are above 1x109 ohms the static control surface may be dirty Clean the surface using the manufacturer s recommended cleaning procedure followed by two clear water rinses and a rinse with 70 Isopro...

Page 5: ...building ground or other suitable ground If you have questions concerning the correct ground refer to EOS ESD Standard 6 0 and or contact a qualified electrician The Resistance to Ground test is the m...

Page 6: ...f five tests per 5 000 square feet 464 5 m2 of floor material whichever is greater A minimum of three of the five tests should be conducted in those areas that are subject to wear or have chemical or...

Page 7: ...ative humidity up to 90 for altitudes up to 2000m unless otherwise noted Pollution degree 2 class 3 equipment Resistance Ranges Test Measurement Open Circuit Internal Function Range Voltage Resistance...

Page 8: ...rohibited by law 3M will not be liable for any loss or damage arising from this 3M product whether direct indirect special incidental or consequential regardless of the legal theory asserted Shipping...

Reviews: