MEASUREMENT:
X
Y
150,08
150,06
150,05
150,04
150,05
150,05
150,07
150,06
150,08
150,06
150,05
150,06
AVERAGE:
The result of this formula will be the basis for further operations:
1. Go to
Calibration
menu and select
XY Calibration
. Confirm selection by pressing
OK
button.
2. Use
up
and
down
buttons from the right panel to select
Print X
value and press
OK
. Use up and down buttons to introduce
the value obtained from
X
axis measurements.
3. Use
up
and
down
buttons from the right panel to select
Print Y
value and press
OK
. Use
up
and
down
buttons to introduce
the value obtained from
Y
axis measurements.
4. After entering all values, confirm changes by selecting
„CALCULATE & SAVE”
. The algorithm will calculate printing parame-
ters according to the measurements made.
Due to this procedure, the next printout from the material, for which the calibration was made, will be completed with the
compensation for thermal contraction of the material in X and Y axes.