Select
[1] Display Current Alarms
to view a list of current alarms, as shown in
Figure 134.
Figure 134
Sample Current Alarm Display
To determine whether or not an alarm-generating condition has been resolved,
clear the current alarms and recheck the Display Current Alarms screen, as follows:
1
From the Display Current Alarm screen, press [Esc] to return to the Fault
Management menu.
2
Select
[2] Clear Current Alarms
.
3
Enter
y
in response to the confirmation prompt to clear the current alarms.
4
Select
[1] Display Current Alarms
to return to the Display Current Alarms screen.
n
Alarm-generating conditions that are still present will regenerate alarms on the
Display Current Alarms screen.
n
Alarm-generating conditions that are no longer present will no longer generate
alarms on the Current Alarm screen.
PathBuilder S330/S310
Alarm Messages
This section lists the alarm messages, meanings of the alarm messages, and
troubleshooting tips for the major errors reported from each of the PathBuilder
S330/S310 interfaces. It contains the following subsections:
n
MCPU and CTX Module (System) Alarms
n
Alarms Common to Several Interfaces
n
DS1/E1 UNI Module Alarms
n
DSX-1/E1 CBR Module Alarms
n
SIM Alarms
n
Voice Compression Module Alarms