Configuring the Voice Compression Module
131
3
From the List Card menu, enter the number corresponding to the slot in which the
VCM you want to configure is installed (
7
or
8
) to open the VCM Configuration
menu. Figure 100 shows the VCM T1-DSX Configuration menu. The VCM E1
Configuration menu is the same.
Figure 100
VCM Configuration Menu
4
Select
[2] Port Configuration
to open the VCM Port Configuration menu.
Figure 101 shows the VCM T1-DSX Port Configuration menu. The VCM E1 Port
Configuration menu is similar.
Figure 101
VCM Port Configuration Menu
5
Set the following port configuration parameters.
LBO
(T1-DSX only)—Line Build Out. LBO refers to the signal
generation/regeneration of the distance between the PathBuilder S330/S310 and
the next crossconnect of FOTs (Fiber Optic Terminal system), in feet: 1-110,
110-220, 220-330, 330-440, 440-550, 550-600 or 600+.