Settings Menu Set-Up
•
Auto Flip - Use this option to set how the camera behaves when full tilt down is reached.
o
Semi - Requires a second tilt down command when at full tilt down to spin camera 180°.
o
Full - Automatically spins the camera 180°
•
Power on Park - When the camera powers up, it will go to a pre-set position. Pre-set 150. Default is off
•
Attack detect - Camera will re-initialize camera motors so that the camera looks back to the original position, if the camera
is physicaly foreced / moved. Default is off.
•
Upright Mount - Can be used to flip the image, so the camera can be used on a pole or a ceilling. Default is pole.
•
Sun Shield - N / A not applicable on Invictus model.
•
IR Lens option - WID option will use the smaller wider area of illumination for the IR and the NAR will use the bigger IR but
will be a more centralized area of illumination.
Settings Menu Pelco-Aux
•
AUX- Used when using Pelco protocol auxiliary commands. Associate a function of the camera to a Pelco Aux command.
Options of auto focus, digital zoom, auto iris, ir, wiper, washer, osd, backlight, white light, auto icr, fast shutter, ir-mono,
mono, park 150, low power, spare 1.
Settings Menu Zoom/Pre sets
•
Digital Zoom - Use this option to enable or disable digital zoom.
•
Proportional - Automatically reduces/increases pan/tilt speed depending on zoom ratio
•
Zoom Speed -The range of speed 5 to 8 and 8 being the fast zoom to slow down the zoom change to 5.
•
AF Al When PTZ - Auto focus/iris will activate when PTZ is used, can be switched off. Default is on.
•
Freeze Pre-sets - This option freezes the image, when moving between pre sets
•
Define Pre-set - Option to enable/disable the setting of pre-sets. Default is on
•
OSD Pre-set six
-
Go into OSD using pre-set 95 and you can switch off OSD access using pre-set 6
Settings Menu Wiper
•
Wiper Rest - Input a rest time for the wiper
•
Wiper on Time (h) - Input a time period for the wiper operation
•
Wiper on Time (m) - Input a time period for the wiper operation
•
Wiper on Time (s) - Input a time period for the wiper operation
•
Wiper Permanent - Enable or disable the permanent wiper time period.
Settings Menu Protocols
•
Pelco D Response -Used on systems using Pelco D protocol where a response from the camera is required.
Do not use if the system doesn't require a response as it will have an effect on the telemetry control of the cameras
•
Pelco Static Mode -Disables PTZ control
•
FV White Lights - Used when using Forward Vision protocol, can be used to select what lamps are controlled from the
lamp command
V12_1_129_03
Page 20 of 49
© 360 Vision Technology Ltd
Summary of Contents for Invictus Hybrid
Page 1: ...V12_1_129_03 Page 1 of 49 360 Vision Technology Ltd ...
Page 8: ...V12_1_129_03 Page 8 of 49 360 Vision Technology Ltd ...
Page 9: ...V12_1_129_03 Page 9 of 49 360 Vision Technology Ltd ...
Page 16: ...V12_1_129_03 Page 16 of 49 360 Vision Technology Ltd ...
Page 24: ...V12_1_129_03 Page 24 of 49 360 Vision Technology Ltd ...
Page 27: ...V12_1_129_03 Page 27 of 49 360 Vision Technology Ltd ...
Page 44: ...V12_1_129_03 Page 44 of 49 360 Vision Technology Ltd ...
Page 45: ...V12_1_129_03 Page 45 of 49 360 Vision Technology Ltd ...
Page 49: ...V12_1_129_03 Page 49 of 49 360 Vision Technology Ltd ...