1O OSD Operation
/
Navigation
Dome menu
•
Seek Preset
•
Start Tour
•
Start Mimic
•
Dome Settings Menu
Define Tour
A tour of presets is stored in the lnvictus as a list of tour points. Each tour point consists of a preset number, the dwell
time for which the lnvictus will pause and the speed parameter that will be used to seek the preset. Each of the four
tours of presets can contain between 2 and 90 points.
When programming a tour of presets it is necessary to first store all the required presets into the lnvictus and to define
the required dwell times and speeds of travel that you will require the lnvictus to use when the tour is started.
A maximum of four individual tours of presets can be stored in each lnvictus. Each tour can have between 2 and 90
points, each point can be a preset in the range 1 to 300. Different points can use any preset number, including repeats
of ones that have been used before. The speed that the camera will travel at to reach the preset can be in the range
1°/sec (slowest) to 100°/sec (fastest). To seek the preset at maximum speed, set speed to 0. The delay (dwell) at each
point is defined in seconds, range 1 to 100.
This page will open on Tour 1, use the joystick left and right to change to another tour. To add item 1, use the joystick
to tilt down. This will highlight the number line so that the tour can be programmed. Use the joystick to navigate along
the number line and zoom in to select the number. This will add the number in to the NEW tour. Add in the figures for
the item/point in the tour using the sequence labeled above (PREDELSPD. PRE is preset position, DEL is delay in
seconds and SPD is speed
at °/second). This is how the camera will be programmed to move to a preset for a period of time at a set speed. All
nine figures must be added into the item. Figures must be added in three for example preset 21 will be added as 021.
021005100 = Move to preset 21 for 5 seconds at 100°/sec
Highlight ACCEPT ITEM and zoom in, this will add the item/point into the tour. The OLD item/point will be shown on
the screen. If these settings are acceptable, highlight the ACCEPT ITEM option and zoom in. There is no need to add
in these points again. Keep adding points until the tour is complete. On the final item/point of the tour highlight and
zoom in on ACCEPT FINAL ITEM. This will complete the tour programming.
Define Mimic
(Before going into the OSD screen to program
a
Mimic tour it is recommended to move the
camera in to the start position, any movement or delay will be recorded once the recording has started.)
When a mimic tour is started, the lnvictus will perform all the actions which were defined when the mimic was
programmed. Up to four mimic tours can be defined.
Highlight and zoom in on START RECORDING, this will allow a mimic tour to be programmed into the camera. The
mimic tour can then be used to playback any manual movement, preset seek or delay. Program a preset to end the
mimic tour program.
Define Preset
Before going into the OSD screen to program a preset, the camera must be in the position required. Once in the OSD
you cannot manually move the camera.
Define Home Function
The camera will perform an ACTION (goto preset, start preset or mimic tour), after a period of inactivity.
Use the NUMBER option to set which preset or tour to start, and the DELAY MINUTES/SECONDS to input the
inactivity time period.
V12_1_129_03
Page 19 of 49
© 360 Vision Technology Ltd
Summary of Contents for Invictus Hybrid
Page 1: ...V12_1_129_03 Page 1 of 49 360 Vision Technology Ltd ...
Page 8: ...V12_1_129_03 Page 8 of 49 360 Vision Technology Ltd ...
Page 9: ...V12_1_129_03 Page 9 of 49 360 Vision Technology Ltd ...
Page 16: ...V12_1_129_03 Page 16 of 49 360 Vision Technology Ltd ...
Page 24: ...V12_1_129_03 Page 24 of 49 360 Vision Technology Ltd ...
Page 27: ...V12_1_129_03 Page 27 of 49 360 Vision Technology Ltd ...
Page 44: ...V12_1_129_03 Page 44 of 49 360 Vision Technology Ltd ...
Page 45: ...V12_1_129_03 Page 45 of 49 360 Vision Technology Ltd ...
Page 49: ...V12_1_129_03 Page 49 of 49 360 Vision Technology Ltd ...