2N LiftIP
®
is set to N/O contact control by default. All the jumpers are on the
jumper link.
CANCEL can be set as N/C too. Slide out the right jumper for N/C.
Voltage control
DC voltage ranging from
can be used.
5 to 48 V
off the configuration jumper link to control CANCEL by
Slide all the jumpers
voltage connection.
Keep only the right jumper on to control CANCEL by voltage disconnection.
Caution
If voltage presence signals a
door, make sure that the power
closed
supply is backed up against power outage.
Warning
Keep polarity (see the cover print).
Induction Loop Connection
Abide by the applicable regulations that may require induction loop installation as a
communicator installation requisite. Connect the induction loop to the LiftIP back
connector. Polarity is arbitrary. The induction loop can be part of the delivery
including a 4 m cable if agreed so.