Configuration Tool
3.4
71
Gateway Connection
The configuration tool can provide the gateway connection either locally via a serial
line (RS232) or remotely via the TPC/IP – Telnet protocol or via a modem. To select
the type of connection, use the
Setting > Communication settings
section.
After selecting the required connection type, click on
OK
to select the proffered type
of connection.
To establish connection with the gateway, click on the
gateway connecting icon, or press the F8 key, or use the
Gateway > Connect gateway menu
.
After a successful connection, the program will ask you for
automatic downloading of the configuration file from the
connected gateway.
Tip
Click on the
on-line configuration
item in the
Gateway control
section
to make the configuration tool automatically try to establish connection
with the gateway according to the selected connection type.
If you are servicing more than one gateway, follow the instruction in
Section Gateway Menu.
Note
The Telnet IP port on the gateway is always set to 23.
The transmission rate of the basic CPU‟s RS232 is always set to
57,600bps.
Main Menu and Button Bar
The following menus are available here: