valve. These pressure-absorbing devices shall be approved mechanical devices. Water pressure-
absorbing devices will be installed as close as possible to the quick closing valve.
13. For optimum performance, the fixture is to operate within the ambient temperature range of 5°C to
44°C.
14. If the supply chord is damaged, it may only be replaced by authorized qualified persons.
INSTALLATION:
1. Mount hanger bracket to wall horizontally level as shown in Roughing-In and Dimensional Drawing.
Note: Adjust height of bracket if bubbler outlet height is required to vary from that shown.
Hanger Bracket MUST be securely anchored to wall with fasteners sufficient to support 3 times
weight of cooler. If wall can not provide adequate support, order and install optional fixture support
carrier.
2. Remove the bottom cover from the water cooler and set aside in a safe place. Save the screws in a
secure location for re-use in later stages of installation.
3. Hang the water cooler on the hanger bracket, ensuring the bracket tabs engage AND seat in the
slots in the back of the water cooler. Verify water cooler is level, left to right AND front to back from
bottom of unit. NOTE: The bubbler stream may be adversely affected if unit is not square and level.
Bottom of unit and louvers should be used as reference to verify unit is square and plumb.
4. Anchor water cooler to wall at other mounting points in base. Shim lower rear mounting points to
level unit if necessary.
5. Thoroughly flush the 3/8” O.D. supply line and then connect water cooler to water supply angle stop
valve (by others) with supplied 3/8” O.D. copper tube.
6. Make up 1-1/4” O.D. p-trap (by others) waste connection.
START UP:
1. Before connecting power supply and assembling bottom cover to water cooler, but after thoroughly
flushing the supply line and connecting it to the fixture, turn on building water supply and check all
connections for leak.
2. Air within the water cooler s
ystem or the structure supply piping will cause an irregular bubbler
outlet stream until purged out by incoming water. Covering the bubbler with a clean cup (or similar
object) is recommended when first activating water cooler to prevent excessive splashing. Depress
the pushbutton until steady water stream is achieved.
3. If water flow requires adjustment, insert a slotted narrow blade screwdriver through the hole
centered on the pushbutton to the flow regulator. Turning clockwise will increase flow and turning
counterclockwise will decrease flow.
4. Recheck all water and drain connections with water flowing through system.
5. With power still NOT connected, carefully manually rotate cooling fan to insure proper clearance
and free fan action.
6. Plug water cooler in to electrical outlet and make sure unit begins to function.
7. Assemble bottom cover to water cooler with screws furnished.
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
WATER COOLERS
A171.8
Page 4 of 13
Revised:
12/26/17
7020-904-001
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of
Содержание Aquaflush Z6000
Страница 3: ...P 1A AND P 1B WATER CLOSET ...
Страница 17: ...P 2 AND P 2B URINAL ...
Страница 31: ...P 3 LAVATORY ...
Страница 36: ...P 5 KITCHEN SINK ...
Страница 42: ...EWC 1 EWC 2 WATER COOLER ...
Страница 56: ...WH 1 WATER HEATER ...
Страница 77: ...HWC 1 RECIRC PUMP ...
Страница 80: ...SP 1 SUMP PUMP ...