1. To install/replace the battery for the backup power feature, remove the access cover (Fig. 1) and install 9 VDC battery
(Fig. 2). After installing battery, press the test button (Fig. 3) to activate the alarm to make sure the battery works properly.
The power indicator, high oil indicator and high water indicator light should illuminate and the buzzer should annunciate. If
using the auxiliary contacts, leave cover off until step 3 is completed. If you are not using them, replace the access cover
(Fig 4).
Installation of the Oil Tector Remote Alarm Continued
(Fig. 1)
(Fig. 2)
(Fig. 3)
(Fig. 4)
Remove Cover To Insert 9v
Battery. Replace Yearly.
Auxiliary Contacts Inside.
Remove Cover To Insert 9v
Battery. Replace Yearly.
Auxiliary Contacts Inside.
2. Determine mounting location for the Oil Tector Remote Alarm. Make sure power outlet is within 5 feet of the alarm (Fig.
5). Make sure the outlet is in on a separate circuit breaker from any other device and not on a switched receptacle to
maintain power integrity. Mount the alarm using two #6 self tapping screws (not included) (Fig. 6). Use #8 plastic anchor if
mounting to sheet rock. (Fig. 7).
(Fig. 5)
(Fig. 6)
(Fig. 7)
Remove Cover To Insert 9v
Battery. Replace Yearly.
Auxiliary Contacts Inside.
Содержание Aquaflush Z6000
Страница 3: ...P 1A AND P 1B WATER CLOSET ...
Страница 17: ...P 2 AND P 2B URINAL ...
Страница 31: ...P 3 LAVATORY ...
Страница 36: ...P 5 KITCHEN SINK ...
Страница 42: ...EWC 1 EWC 2 WATER COOLER ...
Страница 56: ...WH 1 WATER HEATER ...
Страница 77: ...HWC 1 RECIRC PUMP ...
Страница 80: ...SP 1 SUMP PUMP ...