If you had to stop spraying before time (wind, rain, defect…)
and you have in your tank fluid, you can clean the pump and
the system with the water from the clean water tank.
Disengage the P.T.O.
and turn the handle on three-pole valve
as shown in the picture (Position H
2
O).
Turn also the handle on three- pole valve (on the return cycle)
of tank so (shown in the picture), that the long part of valve
handle is turned away from the tank. Open the nozzles; engage
the pump and spray until the clean water tank is empty. Close
the mixers too. When you finish, turn the handles in their first
position. This procedure cleans the system enough, so that
there will not be any problems when the work will be continued.
12.2. REMOVING THE TECHNICAL LEFTOVER
We consider as a technical leftover the fluid in the tank, that
cannot be used - because of the tank shape, fluid in the pump,
hoses and filters. The technical leftover must be watered in a
1:10 proportion and sprayed in the plantation. For thinning of
the technical leftover we can use the water from clear water
tank for system washing.
Close the nozzles and put the pump on, wait until it is good
mixed, and then spray it in the plantation.