4 Safety warnings!

Never place highly combustible materials such as
paper or brushes or highly flammable substances
such as methylated spirits, insulation spray or paint
near the sintering furnace.

Use this furnace only for its intended purpose as
described in this operating manual and carefully
remove all packaging materials and adhesive
tape during the installation.

The appliance may be used indoors only.

Materials that give off toxic gases must not be
sintered.

Fan openings must not be covered over. Danger
of overheating or safety cut-off of the furnace.

The appliance may be connected only to a separate
power socket protected by a 16 A slow-blow
fuse with an earth contact and a 30-mA earth
leakage circuit breaker.

Any interruption in the protective earth conductor
inside and outside the appliance or loosening of
the protective earth connection can lead to the
appliance posing a threat to the operator in the
event of an error. Intentional interruption is not
permissible.

Position the furnace in a free-standing position. A
free space of 200-300 mm must be maintained
around and above the furnace. Immediately
adjoining walls surrounding the appliance should
be made of a non-flammable material. The area
should be well ventilated.

In accordance with fire protection regulations,
install a suitable, recommended, multipurpose,
dry-foam fire extinguisher near the furnace and
make sure that your employees have been
instructed how to use it properly.

Never wear loosely-fitting clothes or clothes that
hang down when operating the furnace. Be
careful when grasping objects in the vicinity of
the furnace. Inflammable material can catch fire
if it comes into contact with a hot surface of the
appliance. The user can sustain severe burns as
a result.

Do not place the furnace in the immediate vicinity
of sources of heat (e.g. burnout furnaces, ceramic
and press furnaces).

Make sure that the furnace has been professio-
nally installed in accordance with our instructions
and that the selected electrical connection is
properly grounded.

Use the grounded appliance power cable IEC
C19 for 230/240 V.

The electrical service must be carefully performed
and must guarantee that the oven is connected
to sufficient voltage. Assign a qualified electrician
to install the proper outlet and voltage supply, so
that you can be sure that the connection is ade-
quate and that no existing circuit is overloaded.

Do not use an extension cable with the furnace.
Ask your electricity supply company about the
electrical connection values that apply to your
local grid.

The temperature may rise more slowly if the 
voltage is too low.

Connections should be checked from time to
time to ensure that they are correctly seated and
that they are not worn or damaged. They should
be tightened again or replaced if necessary.

All cables should be located outside of 
passageways and corridors.

High temperatures can be radiated during operation.

Page

Содержание VARIO S 400

Страница 1: ...www zubler de VARIO S 4 40 00 0 dental technik Operating instructions 07 2019 en Sintering Furnace...

Страница 2: ......

Страница 3: ...t preview mode 1 4 6 Regeneration program 1 4 7 Customized Calibration 2 Maintenance Page 17 2 1 Fuse 2 2 Spare parts 2 3 Technical explanation 3 Data Page 19 3 1 Technical data 3 2 Included 4 Safety...

Страница 4: ...ental technician We help technicians by com bining state of the art technology with future orient ed processes in the VARIO S 400 sintering furnace The software installed in the VARIO S 400 allows an...

Страница 5: ...people Always lift at the base of the unit never lift the furnace using the chamber or the table guide Do not actuate the control panel with hard and or sharp objects Never operate the furnace withou...

Страница 6: ...t the furnace to the power supply using the mains cable provided Switch the furnace on at the main switch After the furnace self test has finished press the yellow Open button 0 4 Installing the appli...

Страница 7: ...tching the furnace on for the first time and inserting the two firing bases execute the Regeneration program Main menu Setup oven Regeneration program Once the lift is completely down place the two in...

Страница 8: ...r changing values Rapid selection circle dialer Step by step yellow keys LCD color display Current temperature Select the desired menu item using the dial or the buttons Press the green Enter Button t...

Страница 9: ...en selected Press the green Enter button to preview the selected program If Preview Mode is activated The furnace will show a preview of the program and ask if you want to run this program Press the g...

Страница 10: ...buttons or dial to select another program or press the red Esc button to go to the Brand menu where you may select another brand that contains the desired program to run Once a program has been selec...

Страница 11: ...y entering the desired let ters and numbers using the buttons or dial Pressing the yellow Left or Right buttons moves the cursor one place to the left or right respectively The letter or number to be...

Страница 12: ...r an individual program is 420 minutes The total individual hold time allowable for any stage is 300 minutes Allowable remaining stage times are automatical ly modified as entries are made Stage 1 Sta...

Страница 13: ...green Enter button to advance and begin editing the program parameters For more information on entering parameters see section 1 3 1 Program Types Select the number of stages desired using the button...

Страница 14: ...es button Escape from deletion by pressing the red No button Once Yes or No is pressed you will be retur ned to the Brand menu where you may select a program to erase or press the red Esc but ton to r...

Страница 15: ...d progs to USB To save programs to the USB Storage device for emailing or later use Make sure your USB Storage device is plugged into the USB port on the side of the oven Use the button or dial to sel...

Страница 16: ...osing is displayed as Off This test is utilized by service personnel and for troubleshooting purposes Factory tests Factory Tests require a password and are only for the use of authorized personnel 1...

Страница 17: ...escription Item Number Heating element 896 0402 Thermocouple type B 896 0401 Tray insulation small 896 0408 Tray insulation large 896 0407 40 g sintering Beads 896 0409 200 g sintering Beads 896 0410...

Страница 18: ...explanation 1 When working with sintering beads gently agita te the objects into the sintering beads Use a maximum of 40g sintering beads per sintering tray 2 Two possibilities to work with the Sinte...

Страница 19: ...Effective Power Apparent Power Performance Data Temperature Color Display Programs Environmental conditions Installation area closed and dry rooms Ambient temperature 18 C to 30 C 64 F to 86 F Relativ...

Страница 20: ...r near the furnace and make sure that your employees have been instructed how to use it properly Never wear loosely fitting clothes or clothes that hang down when operating the furnace Be careful when...

Страница 21: ...opera ting manual in which the repair or replacement must be expressly recommended Every unaut horized attempt to repair replace or open part of your furnace could represent a safety risk and lead to...

Страница 22: ...eakage of waste material Dispose of the fibre waste in sealed containers After direct contact with the skin rinse with water before carefully washing with soap do not use cleaning agents Work clothes...

Страница 23: ......

Страница 24: ...C Zubler Ger tebau GmbH Buchbrunnenweg 26 D 89081 Ulm Jungingen www zubler de dental technik m VS400 en 29 2019 technical changes without notice en...

Отзывы: