1 Operation 

Page

Enter

Setup oven

< 250C

Diagnostics tests

Customize country

Adjust display

Audio Beeps

Set preview mode

Regeneration program

Esc

In the “Setup Oven” menu, parameters are set that
define the basic functions of the furnace for daily
use and are therefore to be entered by the custo-
mer according to individual requirements.

From the “Main Menu”, use the +/- buttons or the
dial to select, "Setup Oven" and press the green
"Enter" button to continue.

1.4.1 Diagnostic Tests

About version

Shows the currently installed software version.

Update Software

Requires the input of a password for updating the
software on the unit. For information about soft-
ware updates or to see if an update is available,
please contact your dealer.

Test Lift

Use the yellow “Up” or “Down” buttons to move
the lift in the respective to direction. Once the lift
has come to the fully UP or fully DOWN position,
ensure the corresponding limit switch status is
displayed as “On” and the opposing is displayed
as “Off”. This test is utilized by service personnel
and for troubleshooting purposes.

Factory tests

Factory Tests require a password and are only for
the use of authorized personnel

1.4.2 Customize country

In this area the language, the date, time and the
units of measurement (metric/imperial) may be
selected.

1.4.3 Adjust display

The brightness of the display is subdivided into
steps. Use the yellow “Dark” / “Light” buttons to
adjust the brightness of the display.

1.4.4 Audio beeps

The "beep" sound can be switched off with yes/no.
The sound is then only emitted when the appliance
is switched on.

1.4.5 Activate preview

With this function you can view the parameters for
the selected program before starting the program.

1.4.6 Regeneration program

When run at monthly intervals; this program
increases the element’s protective layer for 
resistance to oxidation and corrosion, increasing
the service life of the heating elements. 

Follow the displayed prompts to run the program.

1.4.7 Customized Calibration

User can rise or lower the oven temperature. The
real max. end temperature of 1650 °C can not be
exceeded. Customized calibration is only active
between real 250 °C and 1650 °C.

1.4 Setup oven

Содержание VARIO S 400

Страница 1: ...www zubler de VARIO S 4 40 00 0 dental technik Operating instructions 07 2019 en Sintering Furnace...

Страница 2: ......

Страница 3: ...t preview mode 1 4 6 Regeneration program 1 4 7 Customized Calibration 2 Maintenance Page 17 2 1 Fuse 2 2 Spare parts 2 3 Technical explanation 3 Data Page 19 3 1 Technical data 3 2 Included 4 Safety...

Страница 4: ...ental technician We help technicians by com bining state of the art technology with future orient ed processes in the VARIO S 400 sintering furnace The software installed in the VARIO S 400 allows an...

Страница 5: ...people Always lift at the base of the unit never lift the furnace using the chamber or the table guide Do not actuate the control panel with hard and or sharp objects Never operate the furnace withou...

Страница 6: ...t the furnace to the power supply using the mains cable provided Switch the furnace on at the main switch After the furnace self test has finished press the yellow Open button 0 4 Installing the appli...

Страница 7: ...tching the furnace on for the first time and inserting the two firing bases execute the Regeneration program Main menu Setup oven Regeneration program Once the lift is completely down place the two in...

Страница 8: ...r changing values Rapid selection circle dialer Step by step yellow keys LCD color display Current temperature Select the desired menu item using the dial or the buttons Press the green Enter Button t...

Страница 9: ...en selected Press the green Enter button to preview the selected program If Preview Mode is activated The furnace will show a preview of the program and ask if you want to run this program Press the g...

Страница 10: ...buttons or dial to select another program or press the red Esc button to go to the Brand menu where you may select another brand that contains the desired program to run Once a program has been selec...

Страница 11: ...y entering the desired let ters and numbers using the buttons or dial Pressing the yellow Left or Right buttons moves the cursor one place to the left or right respectively The letter or number to be...

Страница 12: ...r an individual program is 420 minutes The total individual hold time allowable for any stage is 300 minutes Allowable remaining stage times are automatical ly modified as entries are made Stage 1 Sta...

Страница 13: ...green Enter button to advance and begin editing the program parameters For more information on entering parameters see section 1 3 1 Program Types Select the number of stages desired using the button...

Страница 14: ...es button Escape from deletion by pressing the red No button Once Yes or No is pressed you will be retur ned to the Brand menu where you may select a program to erase or press the red Esc but ton to r...

Страница 15: ...d progs to USB To save programs to the USB Storage device for emailing or later use Make sure your USB Storage device is plugged into the USB port on the side of the oven Use the button or dial to sel...

Страница 16: ...osing is displayed as Off This test is utilized by service personnel and for troubleshooting purposes Factory tests Factory Tests require a password and are only for the use of authorized personnel 1...

Страница 17: ...escription Item Number Heating element 896 0402 Thermocouple type B 896 0401 Tray insulation small 896 0408 Tray insulation large 896 0407 40 g sintering Beads 896 0409 200 g sintering Beads 896 0410...

Страница 18: ...explanation 1 When working with sintering beads gently agita te the objects into the sintering beads Use a maximum of 40g sintering beads per sintering tray 2 Two possibilities to work with the Sinte...

Страница 19: ...Effective Power Apparent Power Performance Data Temperature Color Display Programs Environmental conditions Installation area closed and dry rooms Ambient temperature 18 C to 30 C 64 F to 86 F Relativ...

Страница 20: ...r near the furnace and make sure that your employees have been instructed how to use it properly Never wear loosely fitting clothes or clothes that hang down when operating the furnace Be careful when...

Страница 21: ...opera ting manual in which the repair or replacement must be expressly recommended Every unaut horized attempt to repair replace or open part of your furnace could represent a safety risk and lead to...

Страница 22: ...eakage of waste material Dispose of the fibre waste in sealed containers After direct contact with the skin rinse with water before carefully washing with soap do not use cleaning agents Work clothes...

Страница 23: ......

Страница 24: ...C Zubler Ger tebau GmbH Buchbrunnenweg 26 D 89081 Ulm Jungingen www zubler de dental technik m VS400 en 29 2019 technical changes without notice en...

Отзывы: