1.
2 - PULSE MC CERAMAY
450C
Edit 56-PULSE PTM 200/2
Program type
I-Press
-Start temp
700C
-Heat rate
60C
-Final temp
920C
-Hold time
20:00
-Extra press time
0:00
-Max press time
10:00
-Pressure
Low
-Vacuum level
720mm
-Opening time
0:00
-Edit done ?
No
➍
The
I
-Press Program
Start temperature
Temperature in the firing chamber at which the program starts.
Heating rate
Temperature increase per minute in order to reach the final temperature.
Final temperature
Temperature at which the ceramic is pressed in the ring.
Hold time
Period during which the ring is maintained at final temperature before pressing.
Extra press time
Additional press time after there has been no movement at the end of the I-Press Process.
Max. Press time
Is the maximum press time desired. Once this time is reached, the press process will stop, independent of the sensor.
Pressure
Select between low and high pressure (2 g pellets = low, 5 g pellets = high pressure 300g ring only).
Vacuum level
Level of vacuum during the pressing program.
Opening time
Decent time of the lift from the chamber to the fully open position.
Edit done
Saving of the program.
We always recommend
using the I-Press program
for pressable ceramics.