Figure 5-3-8 Timing Rule Settings Tab
Configure the QOS parameters, as shown in Table 5-3-7.
Table 5-3-8 QOS Parameters
Parameter Name
Meaning
How to Configure
Min
Points in time when used
together,
Every X Mins when used
separately.
a. Directly input values are points in time,
Value range: 0~59
b. The number X with
“
*/
”
placed ahead means to perform a task every X Mins.
Hr
Points in time when used
together,
Every X Hrs when used separately.
a. Directly input values are points in time,
Value range: 0~23
b. The number X with
“
*/
”
placed ahead means to perform a task every X Hrs.
Date
A day in a month
Manual input.
Value range: 1~31
Multiple dates may be separated with
“
,
”
(the English mark comma)
Month
Month
Manual input.
Value range: 1~12
Multiple months may be separated with
“
,
”
(the English mark comma)
Week
Week
Manual input.
Value range: 1~7
Multiple dates may be separated with
“
,
”
(the English mark comma) and
consecutive days may be represented by
“
x-y
”