45
Flange
F04
F05
F07
F10
F12
ø
d1
65
65
90
125
150
ø
d2
f8
30
35
55
70
85
ø d3
42
50
70
102
125
d4
M6
M6
M8
M10
M12
min.
1,5
3
3
3
3
max.
0,5
0,5
0,5
1
1
h2 min.
12
12
13
16
20
h1 max.
3
3
3
3
3
I 3 min.
15,1
16,1
19,1
22,1
23,1
26,1
30,1
33,1
37,1
37,1
44,1
s
H 11
11
12
14
16
17
19
22
24
27
27
32
e min.
14,1
16,1
18,1
21,2
22,2
25,2
28,2
32,2
36,2
36,2
42,2
ø d5
25
28
40
50
70
h4
Connecting dimensions of
MODACT MOKPED Ex electric actuators
for valves and control devices - connecting with square
The position of the square
hole in end position
of electric actuator.
The position “Opened” is
to the left of the position
“Closed” when viewing in
the direction to the local
indicator of position.
The square hole is according
to DIN 79:2013-02.
Connecting dimensions are
according to DIN 3337 or
ISO 5211.
The position “Z”
(“C”)
of
the square hole for spindle
is identical with the position
“Z”
(“C”)
on the local
indicator of position.
A – connection by square in basic position
B – connection by square turned by 45 °
h2
h1
h4
I3
ø d1
ø d2
ø d5
e
s
d4
A
„O“
“Z” (“C”)
ø d3
„O“
“Z” (“C”)
s
e
B
Содержание MODACT MOKPED 100 Ex
Страница 2: ...ZPA Pe ky a s is certified company in accordance with ISO 9001 as amended...
Страница 50: ...50 NOTES...