ZPA Pecky, a.s. 52 442 Скачать руководство пользователя страница 33

33

    52442  

Sealing ring 125x3 

PN 02 9281.2 

Packing between power gear box

 

 

 

 

and flange with gears

 

Sealing ring 130x3 

PN 02 9281.2 

Packing between control box

 

 

 

 

and power gear box

 

Sealing ring 43x35 

PN 02 9280.2 

Sealing of output shaft in the control box

 

Sealing ring 170x3 

PN 02 9280.2 

Sealing of control box cover

 

Rotary shaft seal 40x52x7 

ČSN 02 9401.0 

Sealing of output shaft in the control box

 

 

 

Rotary shaft seal 40x52x7 

ČSN 02 9401.0 

Sealing of output shaft in the power

 

 

 

 

gear box

 

Rotary shaft seal 16x28x7 

ČSN 02 9401.2 

Sealing of handwheel shaft

 

Potentiometer 2 x 100 

Ω

 

214628650 

Mounting on the control board 

 

99556-3

    52 443  

Sealing ring 160x3 

PN 02 9281.2 

Packing between power gear box

 

 

 

 

and flange with gears 

 

Rotary shaf seal 20x32x7 

ČSN 02 9401.0 

Sealing of handwheel shaft 

 

Sealing ring 95x85 

PN 02 9280.2 

Packing of the rubber-copper sealing  

 

 

 

 

ring in the power box

 

Sealing ring 50x2 

PN 02 9281.0 

Sealing of torque-limit switching

 

 

 

 

spring cover

 

Rotary shaft seal 60x75x8 

ČSN 02 9401.0 

Sealing of output shaft in the power

 

 

 

 

gear box

 

Sealing ring 190x3 

PN 02 9280.2 

Packing between control box and

 

 

 

 

power gear box

 

Rotary shaft seal 55x70x8 

ČSN 02 9401.2 

Sealing of output shaft in the control box

 

Sealing ring 60x50 

PN 02 9280.2 

Sealing of output shaft in the control

 

 

 

 

box cover

 

Sealing ring 190x3 

PN 02 9281.0 

 

Sealing of control box cover

 

Potentiometer 2 x 100 

Ω

 

2340510232 

Mounting on the control board

 

99556-3

    52 442  

Packing 16x22 

224580840 

Packing of threaded plug 

(for oil filling)

    52 443 

Sealing ring 125x5 

ČSN 02 9281.2 

Packing between control box

 

 

 

 

and terminal box

 

Packing 

52 442 - 224591870 

Packing between electric motor

 

 

52 443 - 224642240 

and flange with gears

 

Microswitch CHERRY 

 

CLOSE signalling switch 

(SZ)

 

D - 433 - B8LD 

 

OPEN signalling switch 

(SO)

 

Microswitch CHERRY 

 

CLOSE position-limit switch 

(PZ)

 

D - 433 - B8LD 

 

OPEN position-limit switch 

(PO)

 

Microswitch SAIA 

ČSN 02 9281.2 

CLOSE torque-limit switch 

(MZ)

 

XGK 12-88-J21 

4 - 56480 

OPEN torque-limit switch 

(MO)

 

Sealing ring 180x3 

ČSN 02 9281.2 

Packing of terminal box cover

 

Sealing ring 32x2 

ČSN 02 9281.2 

Packing of inspection hole

 

 

 

 

of local position indicator

 

Inspection hole 

4 - 62847 

Local position indicator cover

 

Sealing ring 10x6 

ČSN 02 9280.2 

Packing of torque-limit switching shaft 

 

Current transmitter CPT 1Az 

2340510393 

1  

Mounting on the control board

 

Current transmitter DCPT3 

214664480 

Mounting on the control board

 

Feeding source for DCPT3 

214651921 

Mounting in the terminal box

List of spare parts of 

MODACT MTN, MTP actuators

(for 5 years of operation)

Designation

Drawing or ČSN 

Standard No.

Application

Содержание 52 442

Страница 1: ...Type numbers 52 442 52 443 Electric Linear Pull rod actuators 4 19 MOUNTING INSTRUCTIONS...

Страница 2: ...ZPA Pe ky a s is certified company in accordance with ISO 9001 as amended...

Страница 3: ...tion or in the tropical atmosphere the anti condensation heater which has been built in all actuators should be always used One or two heater elements should be connected as required Installation of t...

Страница 4: ...tervals The load factor N N R shall be maximum 25 per cent the longest operation cycle N R is 10 minutes The maximum number of switching actions in automatic control mode is 1200 actions per hour The...

Страница 5: ...trol IP 67 Noise Acoustic pressure level A max 85 dB A Acoustic power level A max 95 dB A Tripping thrust At the factory the tripping thrust has been adjusted within the min max range giving in Table...

Страница 6: ...lling switch and the SZ CLOSE signalling switch are used Each of these switches acts only in one direction of output shaft rotation The operating point of the microswitches can be set within the whole...

Страница 7: ...our pole The change over switches are installed in a terminal board box and the control elements on the lid of this terminal board box Position regulator The position regulator built in in the actuato...

Страница 8: ...rminals allowing conductors with a maximum cross section 4 mm2 to be connected Access to the terminal board is obtained after removal of the terminal box cover All control circuits of the electric act...

Страница 9: ...e three phase asynchronous motor 1 drives via countershaft gearing 2 the sun gear of a differential gear unit enclosed in the supporting actuator box power gear transmission 3 In the mechanical power...

Страница 10: ...the transmitter support is positioned at an angle of 180 C with respect to the illustrated position Fig 2a Base plate design with current transmitter 14 66 13 17 67 15 66 16 75 66 12 Legend 12 Torque...

Страница 11: ...direction whereas the segment 24 is designed for the OPEN direction The torque control unit is also fitted with a locking mechanism On operation of the torque limiting switch thismechanism locks this...

Страница 12: ...ranges of adjustment of the signalling switches and the transmitter are required to be changed the position of adjusting wheel K3 should be changed For this purpose the signalling unit should be parti...

Страница 13: ...wheel 62 This wheel is rotated step by step by gear wheels driving cam 57 60 Turning of the cam up to the lever of the CLOSE or OPEN position limit switch PZ or PO causes the switches to change over H...

Страница 14: ...ter 1 x 100 This transmitter has one sided shaft and at its end is fixed a twin wheel 73 composed of gears A and B The principle of drive and transmitter adjustment is equal as at current transmitter...

Страница 15: ...rise up to the resistance value corresponding to the end position open 50 ohms until max 98 ohms Transmitter is set up by this way e Current position transmitters At the first is necessary to set up s...

Страница 16: ...ssary to increase the feeding voltage within the range of recommend values or to decrease total resistance of the current loop R Caution The transmitter CPT 1Az must not be connected without checking...

Страница 17: ...se Press the push button 4 then the push button 20 and keep them depressed until LED blinks When the sense of rotation is changed the end limit positions 4 mA and 20 mA remain valid but the working ra...

Страница 18: ...the actuator is to be stored for a longer period than 3 years then prior to commissioning oil refilling should be made Any manipulation of the equipment at a temperature below 25 C is forbidden Storin...

Страница 19: ...ng to Point 3b Caution The control box cover should be removed so that it is displaced in the direction of extended axis of the actuator output shaft taking care to avoid any damage to the position in...

Страница 20: ...gap that has been thereby disclosed This procedure should be made with the pull rod in the CLOSED position 13 FAILURES AND THEIR REMOVAL Actuator in the end position does not start with motor droning...

Страница 21: ...43 Figs 4 5 6 Type No 52 443 Figs 7 Position transmitter block of local control MODACT MTN MTP actuators 9th place of t no current transmitter 4 20 mA current transmitter 4 20 mA with BMO without BMO...

Страница 22: ...of columns B 150 mm Character on 7th place Ba1I Ba1II Ba1III Ba2I Ba2II Ba2III Bb1I Bb1II Bb1III Bb2I Bb2II Bb2III Bg2I C D E F G H I J K L M P R Spacing of columns Position Closed Thread of coupling...

Страница 23: ...f b ch g e a f b ch g e a 40 a b g a b g max 38 253 max 595 261 max 334 153 100 25 c a d b h g d b h g c a Design 1 M 20 M 20 297 26 A B A B Design 2 Detail of coupling M 20 x 1 5 I M 16 x 1 5 II M 10...

Страница 24: ...g 130 c a 308 d b 352 h g 408 e a 633 f b 677 ch g 733 max 595 max 334 261 325 e a c a d b h g 253 100 153 a b g M20 26 f b ch g 25 215 99 90 e a c a d b h g f b ch g a b g 40 M20 A B Design 1 Detail...

Страница 25: ...ype No 52 443 x1xxx Fig 5 697 436 M30x2 M30 160 261 350 257 835 36 48 60 120 485 376 120 200 with block of terminals with connector External protectivet erminal Local control 697 436 M30x2 M30 160 261...

Страница 26: ...on unit for MODACT MTN MTP 40 electric actuators Type No 52 443 x2xxx design with flange non standard other dimensions and designs of actuators are according to fig 14 15 16 215 160 4x 13 80H8 105 0 2...

Страница 27: ...Q1 MO OPEN torque limit switch SQ2 MZ CLOSE torque limit switch SQ3 PO OPEN position limit switch SQ5 PZ CLOSE position limit switch SQ4 SO OPEN signalling switch SQ6 SZ CLOSE signalling switch SA1 LO...

Страница 28: ...ervomotor MODACT MON MOP Control se styka i a BMO se svorkovnic Wiring diagram of MODACT MTN MTP Control electric actuators with contactors with terminal board P3 0947 Outlet position Control phase BA...

Страница 29: ...servomotor MODACT MON MOP Control se styka i a regul torem ZP2 RE5 se svorkovnic Zapojen elektrick ch servomotor MODACT MON MOP Control se styka i regul torem ZP2 RE5 a BM se svorkovnic with terminal...

Страница 30: ...jumper into clamps t1 t2 Control signal 0 4 20 mA Outlet Position 3 phase motor Brake BR2 blue blue brown brown BRAKE Connect surge voltage protectors to contactor coils O C L R Zapojen elektrick ch s...

Страница 31: ...orem Zapojen elektrick ch servomotor MODACT MON MOP Control se styka i a BMO s konektorem P3 0953 P3M 0954 SA2 O C SA1 L R Wiring diagram of MODACT MTN MTP Control electric actuators with contactors O...

Страница 32: ...iagram of MODACT MTN MTP Control electric actuators with contactors and ZP2 RE5 regulator Wiring diagram of MODACT MTN MTP Control electric actuators with contactors ZP2 RE5 regulator and BMO with con...

Страница 33: ...the control box Sealing ring 60x50 PN 02 9280 2 1 Sealing of output shaft in the control box cover Sealing ring 190x3 PN 02 9281 0 Sealing of control box cover Potentiometer 2 x 100 2340510232 1 Moun...

Страница 34: ...34 NOTES...

Страница 35: ...ary multi turn actuators MODACT MO EEx MOED EEx Explosion proof electric multi turn actuators MODACT MOA Electric multi turn actuators for nuclear power stations application outside containment MODACT...

Страница 36: ...tel 420 321 785 141 9 fax 420 321 785 165 420 321 785 167 e mail zpa zpa pecky cz ZPA Pe ky a s t 5 kv tna 166 289 11 PE KY Czech Republic www zpa pecky cz...

Отзывы: