background image

MEYERTECH LIMITED  

 

 ISSUE 09

 

 

Page 20 

http://www.meyertech.co.uk 

MAN-007 

6.7 ZVR CONFIGURATION 

 

ZVR CONFIG

 allows camera receivers to be configured from the comfort of the keyboard by utilising 

the camera receiver 

OSD

 (On Screen Display) 

The display will show 

 

 

SUPERVISOR 

 CONFIGURATION 

   

 

 

LEVEL 

  ZVR 

CONFIG 

 

STEP 1 

 Press  the 

ENT

 key the display will show 

 

 

SUPERVISOR 

 510 

CONFIG 

 MONITOR-1 

 

 

 

LEVEL 

  ESC 

TO 

EXIT 

 CAMERA 

-1

 

STEP 2 

 Select the camera you want to configure using the numeric keypad and pressing the 

ENT

 key. 

STEP 3 

 Press  the 

MODE

 key. The display will change to  

 

 

SUPERVISOR 

 510 

CONFIG 

 MONITOR-1 

 

 

 

LEVEL 

  PROG 

TO 

SELECT 

 CAMERA 

-1

 

STEP 4

  

Press 

the 

PROG

 key to select the type of receiver: ZVR-

510

, ZVR-

530

, or ZVR-

500

 

STEP 5 

 Press  the 

MODE

 key. The display will change to  

 

 

SUPERVISOR 

 530 

CONFIG 

 MONITOR-1 

 

 

 

LEVEL 

  PROG 

TO 

CONFIG 

 CAMERA 

-1

 

STEP 6

  

Press 

the 

PROG

 key to access the camera receiver 

OSD. 

 The display will show 

 

 

ACCESS GRANTED

   

and then  

ZVR TALK MODE

 

STEP 7-8 

The operation of the menus varies according to the receiver type. 

 

 

  

 

 

ZVR-510 / 500 

STEP 7 

 Follow  the 

OSD

 Menus to configure the camera receiver. Select fields by pressing the 

alphanumeric key corresponding to the capitalised letter in the field name, and 
pressing 

Enter

, or move between fields using the Pan/Tilt joystick and then pressing 

Enter

.  Once a data field is selected, the 

Space

 key toggles its value, or alpanumeric 

data can be entered directly. The 

Shift

 key toggles between alpha and numeric 

modes and the 

DEC

 key between upper and lowercase text. 

STEP 8

 

When you have completed configuring the camera receiver exit all menus until the 
Main menu is displayed. Select either Save changes or Abandon changes, and press 

Enter

.  Now press the 

ESC

 key to exit 

ZVR CONFIG

INFO

 

 

Use the joysticks to position the camera head when requested to do so by the menu - 

this will be indicated by the flashing word HOME. 

 

 

 

  

 

 

ZVR-530 

STEP 7 

 Follow  the 

OSD

 Menus to configure the camera receiver.  

 

The currently selected option is shown in flashing text: Use 

UP

 and 

DOWN

 to move 

the selection, and press 

SELECT 

to choose the current selection. 

Содержание ZVK-007

Страница 1: ...SECURITY with VISION ZVK 007 Keyboard USERS MANUAL...

Страница 2: ...SELECTION 7 3 CLASIK MODE 7 3 1 CLASIK MODE FACILITIES 7 3 2 SELECTING A CAMERA 8 3 3 SELECTING A MONITOR 8 3 4 CAMERA CONTROL 8 3 5 RELEASING CAMERA CONTROL 9 3 6 SALVO SEQUENCE 9 3 7 PLACING A MONI...

Страница 3: ...CESS 16 6 5 KEYBOARD SET UP 16 6 5 1 KEYBOARD CAMERA ACCESS 17 6 5 2 KEYBOARD MONITOR ACCESS 17 6 5 3 KEYBOARD ENGINEERING FACILITIES 18 6 5 4 ZONE SETUP 18 6 6 FEATURE ACCESS 19 6 7 ZVR CONFIGURATION...

Страница 4: ...orrect information contained within this document No part of this document may be reproduced or distributed in any form or by any means without prior written consent from MEYERTECH LIMITED MEYERTECH L...

Страница 5: ...t the screen of the Network cable is connected to the PSU 0V connection STEP 3 Plug the Mains Cube into a convenient power socket STEP 4 Plug the ZVK 007 into the FCC connector on the Network Node box...

Страница 6: ...User Level Access Password allocation and Keyboard Set up has to be carried out from this Level Video Matrix Configuration and Camera Receiver Configuration can also be carried out from this Level To...

Страница 7: ...select the Mode required 3 CLASIK MODE 3 1 CLASIK MODE FACILITIES MONITOR SELECTION 1 64 CAMERA SELECTION 0 512 GLOBAL HOME AUX1 WIPE IRIS AUTO LAMP PRESETS HOME 1 16 PATROL ORDERED RANDOM CAMERA CON...

Страница 8: ...ent to MONITOR STEP 3 Press the ENT Key INFO The display will then either retain the Monitor entered indicating a valid entry or show MONITOR ERROR or MONITOR DENIED 3 4 CAMERA CONTROL The Camera show...

Страница 9: ...PAUSE keys can be used to control the SALVO switching STEP BACK Each time the STEP BACK key is pressed all patterns are stepped back one frame to display the previous camera picture STEP FORWARD Each...

Страница 10: ...camera presets to be recalled in the range 1 16 HOME is a special preset facility which has its own dedicated key STEP 1 Press the PRESET key so the display shows PRESET STEP 2 Enter a PRESET number u...

Страница 11: ...onal Switching facility is a powerful feature capable of switching eight cameras to eight monitors with a single keystroke Eight ZONES can be configured per system keyboard see section 5 10 providing...

Страница 12: ...UX1 WIPE IRIS AUTO LAMP PRESETS HOME 1 16 PATROL ORDERED RANDOM CAMERA CONTROL PAN TILT ZOOM FOCUS IRIS IRIS AUTO MANUAL AUX1 AUX2 LAMP PWI WASH WIPE When the Keyboard is in SITE MODE the display will...

Страница 13: ...cedure STEP 1 Press the Trunk Key labeled as ENC Play INFO If the current trunk was denied a is displayed next to the status to indicate that that the operator has manually accepted the trunk selectio...

Страница 14: ...PC Camera selections are made via the PC GUI with the last camera selected being automatically assigned to the keyboard for Camera Control 6 SUPERVISOR LEVEL 6 1 SUPERVISOR LEVEL FEATURES The SUPERVIS...

Страница 15: ...ow SUPERVISOR PASSWORDS USER LEVEL 1 LEVEL USER 1 SUPERVISOR PASSWORDS USER LEVEL 2 LEVEL USER 2 SUPERVISOR PASSWORDS USER LEVEL 3 LEVEL USER 3 SUPERVISOR PASSWORDS Supervisor Level LEVEL SUPER USER 6...

Страница 16: ...ODE key to cycle through each MODE category The display will show each category and current access status for the USER LEVEL selected SUPERVISOR MODE ACCESS USER LEVEL 1 LEVEL CLASIK GRANT ACCESS INFO...

Страница 17: ...P 2 Use the VCR REW and FF keys to cycle through the system cameras STEP 3 Use the PROG key to Enable or Disable the facility 6 5 2 KEYBOARD MONITOR ACCESS From the MONITOR menu we can enable and disa...

Страница 18: ...ty 6 5 4 ZONE SETUP Zone Set up allows each of the eight Zones available to be configured with monitor and camera numbers Each Zone can be SIZEd independently in the range 2 8 Up to eight Monitor numb...

Страница 19: ...UPERVISOR FEATURE ACCESS LEVEL ESC TO EXIT The first thing we have to do is select the USER LEVEL whose FEATURE ACCESS we wish to configure STEP 1 To select the desired USER LEVEL press the MODE key t...

Страница 20: ...K MODE STEP 7 8 The operation of the menus varies according to the receiver type ZVR 510 500 STEP 7 Follow the OSD Menus to configure the camera receiver Select fields by pressing the alphanumeric key...

Страница 21: ...in CANCEL HOLD Zoom out 6 8 CAMERA CONFIGURATION CAMERA CONFIG allows the supervisor to directly configure a camera through the receiver using the camera s OSD This option works only with camera type...

Страница 22: ...he ENT key the display will show SUPERVISOR ZVM CONFIG LEVEL REQUEST ING ACCESS then REQUEST GRANTED STEP 2 Follow the OSD Menus to configure the video matrix Use the DEL key to move between options a...

Страница 23: ...TOP MODE To select a particular VCR to control use the Numeric Keypad by selecting a VCR number in the range of 1 to 8 Note that you do not have to press the ENT key after selecting a VCR number Using...

Страница 24: ...X MODE log on to the keyboard and press the MODE key until MUX MODE is displayed Press the enter key and the display will show for example MUX MUX 1 OFF MODE CAM OFF To select a particular MUX to cont...

Страница 25: ...s Trouble Shooting Guide should be used in the first instance of encountering any problems with the ZVK 007 If problems persist contact MEYERTECH on the Technical Help line numbers given on page 30 Sy...

Страница 26: ...ns All Conforms to the following Product Specifications EN55022 CLASS B EN50093 EN60950 Amendments 1 2 3 1992 Supplementary Information MEYERTECH declare under our sole responsibility that the product...

Страница 27: ...nties of merchantability or fitness or otherwise Items manufactured by any supplier other than Meyertech Limited shall bear only the warranty made by the manufacturer of that product and Meyertech Lim...

Страница 28: ...UMENT HISTORY ZVK 007 Keyboard Users Manual MAN 007 ISSUE DATE CHANGE RECORD 06 7 October 1997 First Issue in new format 07 18 July 2001 Re issued for Meyertech Limited 08 20 June 2002 Addition of ZVR...

Страница 29: ...MEYERTECH LIMITED ISSUE 09 NOTES Page 29 http www meyertech co uk MAN 007...

Страница 30: ...e Block One Southlink Business Park Oldham England OL4 1DE Sales Support 44 0 161 628 8406 44 0 161 628 9811 Email sales meyertech co uk Technical Support 44 0 1724 278 833 Email technical meyertech c...

Отзывы: