4
3
.
System Parameter Setting Definition
3.1 Electric /air-powered machine type parameter setting
User Parameter ( Under the normal mode press [P] key to access)
No
Function parameters
Range
Default
Description
P-01
Maximum Sewing Speed
(
r/min
)
100-6000
5000
Maximum sewing speed setting
P-02
Needle stop positioning
selection
0-1
0
0:Up needle position
1: Down Needle position
P-03
Start sewing speed
(
r/min
)
100-6000
4000
With trimming function: the speed setting for front
sensor trigger start-up and Back sensor signal finish
(before trimming)
P-04
Start-up mode
0-1
1
(
Valid for full-automatic mode
)
0
:
Automatic mode
(
start-up
)
1
:
Foot control mode
(
Start-up by Front toe
down the pedal
)
P -05
Automatic/semi-automatic
mode selection
0-1
1
(
P-06 is turn on
)
0
:
Semi-automatic
1
:
Automatic
P -06
Auto sensing switch
0-1
1
0
:
OFF
(
Full manual mode is turn on
)
1
:
ON
(
It can execute automatic/ semi-automatic mode
also match with P-05 use
)
P -07
Auto trimming switch
0-3
3
0
:
OFF
1
:
Front trimming
(
Mid-sensor receive signal then
trimming
)
2
:
Rear trimming
(
Back-sensor receive signal after
finished trimming
)
3
:
First and later trimming
key to save current value.
4
Sensor sensitivity
adjustment
1. Under the normal mode interface long-press
key, it can direct access sensor
sensitivity adjustment interface:
2. Please remove cloth after Three-sensor, press [S] key;
3. Please cover cloth after three-sensor, press [S] key
,
finished setting.
5
Piecework function
Under the normal mode interface press
and
key at the same time
,
press
or
key it can increase or decrease operation to the totoal piece manually
;
piecework other corresponding parameter setting:
Press
and
keys at the same time to turn on the machine, press
key to find
P-75 setting pieces of alarm, find P-76 setting alarm pieces plus minus sequence.
Содержание QD2622 Series
Страница 9: ...9 ...