8
want effects.
Senior parameter setting ( press P + S key at the same time to turn on the machine access)
P-70
Model selection
0-1
0
0
:
Horizontal knife type 1
:
Side knife type
P-71
Maximum sewing speed
limitation
(
r/min
)
100-8000
6000
Maximum sewing speed limitation
P-72
Manually up positioning
adjustment
0-1439
Through hand-wheel direction, clockwise turn
hand-wheel to up position press [S] to save the current
value.
P-73
Manually down positioning
adjustment
0-1439
Through hand-wheel direction, clockwise turn
hand-wheel to down position then press [S] to save
current value.
P-74
Parameter reference
0-4
1
Use up and down key shift:
N1
:
Control box software version
N2
:
Panel software version
N3
:
Rotation
N4
:
Pedal AD
P-75
Alarm pieces
0-9990
0
P-76
Alarm pieces plus minus
sequence
0-1
0
0
:
minus 1
:
plus
P-77
Zero-point angle setting
Firstly to enter P-48 close the needle goes up as power
on, turn off the machine then restart the machine,
enter this item press
automatic to find zero-point,
till machine stops, press
key to save, then enter
to P-48, turn on the needle goes up as power on.
P-78
Suction bucket type
0-2
1
0
:
with brush 1: without brush 2
:
valve
3.2 Side knife type system parameter setting
User Parameter ( Under the normal mode press P key to access)
No
Function parameters
Range
Default
Description
P-01
Maximum Sewing Speed
(
r/min
)
100-6000
5000
Maximum sewing speed setting
P-02
Needle stop positioning
selection
0-1
0
0
:
Up needle position
1
:
Down Needle position
P-03
Start sewing speed
(
r/min
)
100-6000
4000
With trimming function: the speed setting for front
sensor trigger start-up and Back sensor signal finish
(before trimming)
P-04
Start-up mode
0-1
1
(Valid for full-automatic mode)
0
:
Automatic mode
(
start-up
)
1
:
Foot control mode
(
Start-up by Front toe
down the pedal
)
Содержание QD2622 Series
Страница 9: ...9 ...