12
P-65
The strength of mid-sensor
0%-100%
80%
Adjustment mid-sensor strength
P-66
The strength of back sensor
0%-100%
80%
Adjustment back sensor strength
P-67
The sensitivity of back
sensor
0-700
440
In order to adapt different cloth material setting
back-sensor receive strength.
P-68
Cutter speed by manually
(
r/min
)
100-6500
1000
P-69
Response time of back
sensor
(
ms
)
0-3000
0
Response time of back-sensor, when sewing such as
mesh cloth can adjust this item, then can achieve you
want effects.
Senior parameter setting ( press P + S key at the same time to turn on the machine access)
P-70
Model selection
0-1
1
0
:
Horizontal knife type 1
:
Side knife type
P-71
Maximum sewing speed
limitation
(
r/min
)
100-8000
6000
Maximum sewing speed limitation
P-72
Manually up positioning
adjustment
0-1439
Through hand-wheel direction, clockwise turn
hand-wheel to up position press S to save the current
value.
P-73
Manually down positioning
adjustment
0-1439
Through hand-wheel direction, clockwise turn
hand-wheel to down position then press S to save
current value.
P-74
Parameter reference
0-4
1
Use up and down key shift
:
N1
:
Control box software version
N2
:
Panel software version
N3
:
Rotation
N4
:
Pedal AD
P-75
Alarm pieces
0-9990
0
P-76
Alarm pieces plus minus
sequence
0-1
0
0
:
minus 1
:
plus
P-77
Zero-point angle setting
Firstly to enter P-48 close the needle goes up as power
on, turn off the machine then restart the machine,
enter this item press
automatic to find zero-point,
till machine stops, press
key to save, then enter
to P-48, turn on the needle goes up as power on.
P-78
Suction bucket type
0-2
1
0
:
with brush 1: without brush 2
:
valve
4
.
Error Code List
Error Code
Problem
STATUS / MEASUREMENT
E01
1) When power ON, detected main voltage too
high
Turn off the system power supply, and detect
whether the supply voltage is correct. (Or
Содержание QD2622 Series
Страница 9: ...9 ...