- 2 -
2. Check to be sure your power source is adequate to handle the amperage
requirements of the motor as indicated on the pump or unit I.D. tag.
4. Maximum operating temperature must not exceed 104 °F (40 °C).
5. Do not use cleaning products containing bleach in the toilet tank, toilet or
attached
as they will degrade the pump seals.
SEE BELOW FOR LIST OF CAUTIONS
3. All plumbing (discharge and
vent) must
be
installed
to meet local codes.
Unit must be vented. Do not use an automatic plumbing vent
6. This product is designed for use with one toilet only.
1. Repair and service should be performed by a Zoeller Authorized Service and
5. All fixtures connecting to the system must be on the same
level.
SEE BELOW FOR LIST OF NOTES
NOTES
4. Pumps with the “cCSAus”
mark
Pumps with the “cCSAus” mark
and/or the
“US”
mark
are
tested to UL
Standard
UL778.
are
to CSA Standard
C22.2 No.108.
2.
3. The grinder pump is designed for use in Qwik Jon Premier units only. It is not
designed for use in other applications.
Recommended for installations up to 7 m of vertical lift. Reference Step 7
for maximum pipe length calculations.
LIMITED WARRANTY
Manufacturer warrants, to the purchaser and subsequent owner during
the warranty period, every new product to be free from defects in material
and workmanship under normal use and service, when properly used
and maintained, for a period of one year from date of purchase by the
end user, or 18 months from date of original manufacture of the product,
whichever comes first. Parts that fail within the warranty period, one
year from date of purchase by the end user, or 18 months from the
date of original manufacture of the product, whichever comes first, that
inspections determine to be defective in material or workmanship, will be
repaired, replaced or remanufactured at Manufacturer's option, provided
however, that by so doing we will not be obligated to replace an entire
assembly, the entire mechanism or the complete unit. No allowance
will be made for shipping charges, damages, labor or other charges
that may occur due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for
any material or product that has been disassembled without prior
approval of Manufacturer, subjected to misuse, misapplication, neglect,
alteration, accident or uncontrolled weather event; that has not been
installed, operated or maintained in accordance with Manufacturer's
installation instructions; that has been exposed to outside substances
including but not limited to the following: sand, gravel, cement, mud,
tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents,etc.),
or other abrasive or corrosive substances, wash towels or any other
abusive entity, etc. in all pumping applications. The warranty set out
in the paragraph above is in lieu of all other warranties expressed or
implied; and we do not authorize any representative or other person
to assume for us any other liability in connection with our products.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR
SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES OR
BREACH OF EXPRESSED OR IMPLIED WARRANTY; AND
ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR
PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO
THE DURATION OF THE EXPRESSED WARRANTY.
Some jurisdictions do not allow limitations on the duration of an implied
warranty, so the above limitation may not apply to you. Some jurisdictions
do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have
other rights which vary from jurisdiction to jurisdiction.
of part(s) or additional information pertaining to our warranty.
Contact authorized distributors to obtain any needed repair or replacement
HELPFUL HINTS FOR EASY INSTALLATION
DO’S AND DON'T’S,
continued
DO’S AND DON'T’S FOR INSTALLING A UNIT
1. DO read all installation material with the unit.
2. DO inspect unit for any visible damage caused by shipping.
Contact dealer if unit appears to be damaged.
3. DO clean all visible debris from the unit.
4. DO always lift the unit by the built-in handles.
5. DO always disconnect pump from power source before handling.
DO always connect to a separately protected and properly grounded
ground fault protected circuit. DO NOT ever cut, splice or damage
power cord. DO NOT carry or lift pump by its power cord. DO NOT
use an extension cord.
6. DO install a ball or gate valve and a union in the discharge line
downstream of the check valve.
7. DO test pump immediately after installation to be sure that the system
is working properly.
8. DO review all applicable local and national codes and verify that the
installation conforms to each of them.
9. We DO NOT recommend this product be connected to utilities other than
those found in a normal bathroom application. Washing machines and
dishwashers are examples of equipment that we DO NOT recommend.
10. DO inspect and test system for proper operations at least every 3 months.
1. Read all instructions before beginning installation.
2. Be sure the floor is level within 1/8" (3 mm).
3. Install vent pipe seal with flange side of seal on the outside of lid.
4. Use soapy water to lubricate all seals to aid installation.
5. Install rubber coupling/union in vent line to aid disassembly.
6. Do not over torque toilet mounting screws.
7. Do not use an automatic plumbing vent device.
8. Obtain model number and date code, and record information in the
space provided on the front of this manual. Refer to this information
when calling the factory. Register your product online using the
Product Registration information provided on ZT0450_ESFc.
7. Conductor color coding: Type 1 - Line (Brown), Neutral (Blue), Ground
(Yellow / Green). Type 2 - Line (Black), Neutral (White), Ground (Green).
8. Prop65 Warning for California residents: Cancer and Reproductive Harm-
www.P65Warnings.ca.gov.
9.
Risk of explosion:
Do not use the pump for flammable liquids such as
diesel oil, petrol or similar liquids.
In instances where property damages are incurred as a result of an alleged product failure,
the property owner must retain possession of the product for investigation purpose.
1.
Warranty Center. (Consult Factory.)
This unit is not designed to handle any material other than human waste
and toilet paper. The list of items that should not be used with this system
includes, but is not limited to: feminine sanitary products, condoms, cotton
balls and swabs, baby wipes, paper towels, etc.