WARNING

•  ELECTRICAL SHOCK ALERT.

Do not disassemble the motor housing. The motor has NO repairable internal parts and disassembly may 

cause dangerous electrical wiring issues.

•  ELECTRICAL SHOCK ALERT.

Before installing this product, have the electrical circuit checked by an electrician to ensure proper 

grounding. All electrical installations must conform to the National Electric Code and all local codes.

•  ELECTRICAL SHOCK ALERT.

Connect the AC adapter to a properly-grounded 115 volt circuit equipped with a Ground Fault Circuit 

Interrupter (GFCI) device. Make sure the electrical supply circuit is equipped with fuses or circuit breakers 

with a minimum capacity of 15 amps.

•  ELECTRICAL SHOCK ALERT.

Never use an extension cord.

•  ELECTRICAL SHOCK ALERT.

Do not remove or replace the power cord.

•  ELECTRICAL SHOCK ALERT.

Protect electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. 

•  ELECTRICAL SHOCK ALERT.

Do not lift pump by the power cord.

•  PERSONAL INJURY ALERT.

Do not touch an operating motor housing. The motor is designed to operate at high temperatures.

•  PERSONAL INJURY ALERT.

Release all pressure and drain all water from the system before servicing any component.

•  PERSONAL INJURY ALERT.

Secure discharge line before starting pump. An unsecured discharge line can cause personal injury and/or 

property damage.

•  PERSONAL INJURY ALERT.

Wear safety glasses at all times when working with pumps.

•  PROP65 WARNING FOR CALIFORNIA RESIDENTS: 

Cancer and Reproductive Harm  – www.P65Warnings.ca.gov

CAUTION

•  PERSONAL INJURY OR PRODUCT DAMAGE MAY RESULT.

The AC adapter operates on 115 volts. Make certain that the power source conforms to the requirements of 

your equipment.

•  PRODUCT DAMAGE MAY RESULT.

The continuous operating water temperature for this pump must not exceed 104°F (40°C).

•  PRODUCT DAMAGE MAY RESULT.

This pump is designed to pump water only. It has not been evaluated for pumping chemicals or corrosive 

materials. This pump is not designed for pumping effluent or sewage and should not be used in 

applications involving salt water or brine.

•  PRODUCT DAMAGE MAY RESULT.

Inspect the pump regularly for damage and perform routine maintenance as needed. Remove any debris 

that may build up around the float.

•  PRODUCT AND/OR PROPERTY DAMAGE MAY RESULT.

This pump is not designed for continuous operation.

SAFETY INFORMATION

3

© 2020. All rights reserved.

WARNING

•  ELECTRICAL SHOCK ALERT.

Do not disassemble the motor housing. The motor has NO repairable internal parts and disassembly may 

cause dangerous electrical wiring issues.

•  ELECTRICAL SHOCK ALERT.

Before installing this product, have the electrical circuit checked by an electrician to ensure proper 

grounding. All electrical installations must conform to the National Electric Code and all local codes.

•  ELECTRICAL SHOCK ALERT.

Connect the AC adapter to a properly-grounded 115 volt circuit equipped with a Ground Fault Circuit 

Interrupter (GFCI) device. Make sure the electrical supply circuit is equipped with fuses or circuit breakers 

with a minimum capacity of 15 amps.

•  ELECTRICAL SHOCK ALERT.

Never use an extension cord.

•  ELECTRICAL SHOCK ALERT.

Do not remove or replace the power cord.

•  ELECTRICAL SHOCK ALERT.

Protect electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. 

•  ELECTRICAL SHOCK ALERT.

Do not lift pump by the power cord.

•  PERSONAL INJURY ALERT.

Do not touch an operating motor housing. The motor is designed to operate at high temperatures.

•  PERSONAL INJURY ALERT.

Release all pressure and drain all water from the system before servicing any component.

•  PERSONAL INJURY ALERT.

Secure discharge line before starting pump. An unsecured discharge line can cause personal injury and/or 

property damage.

•  PERSONAL INJURY ALERT.

Wear safety glasses at all times when working with pumps.

•  PROP65 WARNING FOR CALIFORNIA RESIDENTS: 

Cancer and Reproductive Harm  – www.P65Warnings.ca.gov

CAUTION

•  PERSONAL INJURY OR PRODUCT DAMAGE MAY RESULT.

The AC adapter operates on 115 volts. Make certain that the power source conforms to the requirements of 

your equipment.

•  PRODUCT DAMAGE MAY RESULT.

The continuous operating water temperature for this pump must not exceed 104°F (40°C).

•  PRODUCT DAMAGE MAY RESULT.

This pump is designed to pump water only. It has not been evaluated for pumping chemicals or corrosive 

materials. This pump is not designed for pumping effluent or sewage and should not be used in 

applications involving salt water or brine.

•  PRODUCT DAMAGE MAY RESULT.

Inspect the pump regularly for damage and perform routine maintenance as needed. Remove any debris 

that may build up around the float.

•  PRODUCT AND/OR PROPERTY DAMAGE MAY RESULT.

This pump is not designed for continuous operation.

SAFETY INFORMATION

Содержание BASEMENT SENTRY STBC201Q

Страница 1: ...department at 1 800 584 8089 7 30 a m 5 00 p m EST Monday Friday ATTACH YOUR RECEIPT HERE 24 7 BASEMENT PROTECTION Espa ol p 23 PN 156409 A SW1505 A B Y BasementSentry com Zoeller is a registered tra...

Страница 2: ...Keep sparks and flame pilot light away from battery FIRE EXPLOSION HAZARD Pump only clear water Do not pump flammable or explosive fluids such as gasoline fuel oil kerosene etc Do not use in a flammab...

Страница 3: ...OR PROPERTY DAMAGE MAY RESULT This pump is not designed for continuous operation SAFETY INFORMATION 3 2020 All rights reserved WARNING ELECTRICAL SHOCK ALERT Do not disassemble the motor housing The m...

Страница 4: ...ump system or a competitive brand all use batteries that give o gaseous by products when charging Some of these by products can produce a rotten egg odor Also some of these by products can cause a CO...

Страница 5: ...existing discharge piping and cut 1 1 2 in Sched 40 PVC to this size Install 1 1 2 in flex coupling or 1 1 2 in union between pipe connected to the pump and the discharge piping Glue all pipe and fit...

Страница 6: ...oller to the battery terminals Connect positive lead to positive terminal on the battery and black negative lead to the negative battery terminal NOTE If wires are not connected properly a loud consta...

Страница 7: ...STATUS BATTERY DC PUMP 24 7 BASEMENT PROTECTION USB RESET FLOAT DC PUMP FUSE 30 AMP 1 800 584 8089 BasementSentry com DC POWER 15V DC 1 6A Test 2 SILENCE TEST by FW2065 A P L U S AC POWER FLOAT STATUS...

Страница 8: ...SID and password To prevent the most common troubleshooting issues double check to be sure you know exactly how the password is spelled including capitalization Verify that your mobile device has work...

Страница 9: ...t you will need to click the link at the bottom of the home screen to create an account 2 3 Once you re logged in to your account create locations by touching the from the Locations screen 2 Open your...

Страница 10: ...to the cloud the Basement Sentry controller may immediately update its firmware over the air OTA if an update is available If an update is taking place the Z Control LED will flicker for up to one min...

Страница 11: ...ce to a different location in your account Use the Mobile App iOS and Android Continued 8 8 Open the Basement Sentry app to explore current status configuration settings and commands available such as...

Страница 12: ...n the top of the controller NOTE The above list also helps to troubleshoot connectivity issues If the controller still will not connect after trying the above suggestions follow the same steps to conn...

Страница 13: ...ore this and connect to it anyway 2 Select the Basement Sentry SSID The last 4 digits underlined will match the first 4 digits of the controller Device ID Connecting with your mobile device or compute...

Страница 14: ...id log in to your account or create one at zcontrolcloud com Connecting with your mobile device or computer Continued 5 Choose the Add New Device button next to the location you want the controller Fo...

Страница 15: ...ontroller s alert history on the Z Control Cloud will also be updated with the firmware upgrade information and notification to email accounts will occur START UP AND OPERATION The Basement Sentry con...

Страница 16: ...ERY DC PUMP 24 7 BASEMENT PROTECTION USB RESET FLOAT DC PUMP FUSE 30 AMP 1 800 584 8089 BasementSentry com DC POWER 15V DC 1 6A All lights will be green when plugged into 115V outlet 2 START UP AND OP...

Страница 17: ...p is above the inlet of the primary pump Press Silence for 3 seconds to cancel the alarm and reset the unit CAUTION Continuously running the pump dry may cause overheating and damage the pump Once the...

Страница 18: ...com DC POWER 15V DC 1 6A Press and hold three seconds to reset system 9 SILENCE TEST by FW2065 A P L U S AC POWER FLOAT STATUS BATTERY DC PUMP 24 7 BASEMENT PROTECTION USB RESET FLOAT DC PUMP FUSE 30...

Страница 19: ...t off after the water level is lowered and the float drops to the off position Hold the Silence reset button for three seconds to reset the controller and clear any alarms or indicators C Plug the con...

Страница 20: ...s power has been restored and the float switch is in the off position If immediate use is required replace old battery with a fully charged battery NOTE The pump may continue to run on a low battery w...

Страница 21: ...Float switch in on position for 3 seconds or more but pump won t run Pump is obstructed Remove pump and clear any debris from impeller or pump cavity Pump runs but pumps water intermittently Incoming...