PREPARATION

Estimated Installation Time: 

1-2 hours

Materials required for assembly: 

 Basement Sentry brand deep cycle battery 1-1/2-in. Schedule 40 

PVC pipe and fittings, PVC primer and glue, Phillips screw driver, hand saw

GENERAL PUMP INFORMATION

SPECIFICATIONS

PUMP

PERFORMANCE IN GALLONS PER MINUTE

0 FT.

5 FT.

10 FT.

15

28 FT.

115V Primary Pump

42

38

30

12

-

12V Backup Pump

45

43

35

27

Shut Off

This complete system features built-in WiFi to provide mobile monitoring and alerts. The 

system includes a high-capacity primary pump, back-up pump, controller, alarm system, 

battery charger, PVC pipe with fi ttings and an inline check valve.

This combination system will replace an existing primary sump pump for premium protection 

against basement fl ooding. It is designed protect your home during power outages.

Choose this pump if your sump basin is at least 18-in. wide by 22-in. deep. 
Place the battery in a cool, dry, well-ventilated area on a shelf or protective plywood board. 
Carbon Monoxide Detectors
Whether you have a Basement Sentry backup pump system or a competitive brand, all use 

batteries that give off  gaseous by-products when charging. Some of these by-products can 

produce a rotten egg odor. Also, some of these by-products can cause a CO detector to falsely 

activate. In order to help prevent false activation, Basement Sentry recommends moving the 

battery as far away from the CO detector as possible or, if necessary, vent the battery to the 

exterior. Basement Sentry provides the previous statements only as guidelines to help prevent 

false activation of the CO detector. In no way are they meant to supersede the instructions that 

accompany the detector, nor do they supersede advice from the CO detector manufacturer.

If the audible alarm associated with your CO detector is activated, we recommend the 

following actions:
1.  Take immediate action for personal safety as recommended in the CO detector literature.
2.  Contact the appropriate agency to determine if the CO is being produced by your furnace, 

water heater, or any other device which uses natural gas.

3. 

If you are certain that no CO is being produced, a charging battery may be producing 

gaseous by-products which are causing the CO detector to activate. Contact the 

manufacturer and ask for recommendations to prevent the alarm activation.

Содержание BASEMENT SENTRY STBC201Q

Страница 1: ...department at 1 800 584 8089 7 30 a m 5 00 p m EST Monday Friday ATTACH YOUR RECEIPT HERE 24 7 BASEMENT PROTECTION Espa ol p 23 PN 156409 A SW1505 A B Y BasementSentry com Zoeller is a registered tra...

Страница 2: ...Keep sparks and flame pilot light away from battery FIRE EXPLOSION HAZARD Pump only clear water Do not pump flammable or explosive fluids such as gasoline fuel oil kerosene etc Do not use in a flammab...

Страница 3: ...OR PROPERTY DAMAGE MAY RESULT This pump is not designed for continuous operation SAFETY INFORMATION 3 2020 All rights reserved WARNING ELECTRICAL SHOCK ALERT Do not disassemble the motor housing The m...

Страница 4: ...ump system or a competitive brand all use batteries that give o gaseous by products when charging Some of these by products can produce a rotten egg odor Also some of these by products can cause a CO...

Страница 5: ...existing discharge piping and cut 1 1 2 in Sched 40 PVC to this size Install 1 1 2 in flex coupling or 1 1 2 in union between pipe connected to the pump and the discharge piping Glue all pipe and fit...

Страница 6: ...oller to the battery terminals Connect positive lead to positive terminal on the battery and black negative lead to the negative battery terminal NOTE If wires are not connected properly a loud consta...

Страница 7: ...STATUS BATTERY DC PUMP 24 7 BASEMENT PROTECTION USB RESET FLOAT DC PUMP FUSE 30 AMP 1 800 584 8089 BasementSentry com DC POWER 15V DC 1 6A Test 2 SILENCE TEST by FW2065 A P L U S AC POWER FLOAT STATUS...

Страница 8: ...SID and password To prevent the most common troubleshooting issues double check to be sure you know exactly how the password is spelled including capitalization Verify that your mobile device has work...

Страница 9: ...t you will need to click the link at the bottom of the home screen to create an account 2 3 Once you re logged in to your account create locations by touching the from the Locations screen 2 Open your...

Страница 10: ...to the cloud the Basement Sentry controller may immediately update its firmware over the air OTA if an update is available If an update is taking place the Z Control LED will flicker for up to one min...

Страница 11: ...ce to a different location in your account Use the Mobile App iOS and Android Continued 8 8 Open the Basement Sentry app to explore current status configuration settings and commands available such as...

Страница 12: ...n the top of the controller NOTE The above list also helps to troubleshoot connectivity issues If the controller still will not connect after trying the above suggestions follow the same steps to conn...

Страница 13: ...ore this and connect to it anyway 2 Select the Basement Sentry SSID The last 4 digits underlined will match the first 4 digits of the controller Device ID Connecting with your mobile device or compute...

Страница 14: ...id log in to your account or create one at zcontrolcloud com Connecting with your mobile device or computer Continued 5 Choose the Add New Device button next to the location you want the controller Fo...

Страница 15: ...ontroller s alert history on the Z Control Cloud will also be updated with the firmware upgrade information and notification to email accounts will occur START UP AND OPERATION The Basement Sentry con...

Страница 16: ...ERY DC PUMP 24 7 BASEMENT PROTECTION USB RESET FLOAT DC PUMP FUSE 30 AMP 1 800 584 8089 BasementSentry com DC POWER 15V DC 1 6A All lights will be green when plugged into 115V outlet 2 START UP AND OP...

Страница 17: ...p is above the inlet of the primary pump Press Silence for 3 seconds to cancel the alarm and reset the unit CAUTION Continuously running the pump dry may cause overheating and damage the pump Once the...

Страница 18: ...com DC POWER 15V DC 1 6A Press and hold three seconds to reset system 9 SILENCE TEST by FW2065 A P L U S AC POWER FLOAT STATUS BATTERY DC PUMP 24 7 BASEMENT PROTECTION USB RESET FLOAT DC PUMP FUSE 30...

Страница 19: ...t off after the water level is lowered and the float drops to the off position Hold the Silence reset button for three seconds to reset the controller and clear any alarms or indicators C Plug the con...

Страница 20: ...s power has been restored and the float switch is in the off position If immediate use is required replace old battery with a fully charged battery NOTE The pump may continue to run on a low battery w...

Страница 21: ...Float switch in on position for 3 seconds or more but pump won t run Pump is obstructed Remove pump and clear any debris from impeller or pump cavity Pump runs but pumps water intermittently Incoming...

Страница 22: ...er than for what it was designed and manufactured RETURN OF WARRANTED COMPONENTS Any item to be repaired or replaced under this warranty must be returned to the manufacturer at Kendallville Indiana or...

Отзывы: