6
© 2020. All rights reserved.
5.
Connect backup pump and fl oat leads to the
controller
To controller
4
INSTALLATION INSTRUCTIONS
SILENCE
TEST
by
FW2065 A
P L U S
AC
POWER
FLOAT
STATUS
BATTERY
DC
PUMP
24/7 BASEMENT
PROTECTION
USB
RESET
FLOAT
DC
PUMP
FUSE
30 AMP
1-800-584-8089
BasementSentry.com
DC POWER
+ 15V DC 1.6A
From float
From
backup
pump
From battery
From battery
charger
5
4. Place the battery inside the battery box and connect
the leads from the controller to the battery terminals.
Connect positive (+) lead to positive terminal on the
battery and black negative (-) lead to the negative
battery terminal.
NOTE: If wires are not connected properly, a loud,
constant audible alarm will sound until the leads are
attached to the correct terminals.
6.
Plug the controller into a GFCI-protected 115V
outlet.
NOTE: The primary pump and controller should
be on separate circuits.
Test for backup pump operation by adding
water to the sump basin.