6

7

IL1360

4

IL1359

Pump

Flow

Arrow

3b

IL1104

Water Level

25 ft.

Max

Suction 

Lift

1 in.  

Discharge Pipe

1-1/4 in.

Suction

Pipe

Discharge 

to Home 

Pipe 

Support

Foot Valve

3a

IL1358

Glue

2

IL1357

Glue

1

3a.   NOTE: For drilled (cased) wells, a foot 

valve is required in the well at the end of 

the pipe to maintain prime. 

1.   Make the connection to your well first. Wrap 

all threaded fittings with pipe tape 5 times and 

then apply a pipe paste (pipe dope) to ensure 

an air tight connection. 

  CAUTION:  

Dry-fit entire assembly to ensure proper fit before gluing or taping parts.

  CAUTION:  

Follow all proper gluing procedures as specified by the glue manufacturer. Always 

glue in a vertical direction whenever possible to prevent glue from dripping inside pipe or fittings

  CAUTION:  

Use pipe tape and pipe paste compound on all male threads. Tighten with wrench to 

a snug fit and add another 1/4 turn to ensure proper seal.

3b.  For driven wells, a check valve is required 

at the top of the well to maintain prime. Flow 

arrow must point toward pump.

4.  Finish the connection to your well with 

additional pipe and fittings as needed. 

WELL TO PUMP CONNECTION (SUCTION PIPE)

2.   The use of a union (optional) will assist with 

easy connection and disconnect.

1

IL1361

Tape

1.  Begin the connection to the pressure tank. 

Using a 1 in. x 3 in. galvanized nipple, wrap 

the threads 5 times with pipe tape or apply 

pipe paste (pipe dope) and install in top of 

pump.

PUMP TO PRESSURE TANK CONNECTION (DISCHARGE PIPE)

Содержание 1461-0006

Страница 1: ...hase Date Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 584 8089 7 30 a m 5 00 p m EST Monday Friday ATTACH YOUR RECEIPT HERE Zoeller...

Страница 2: ...read and understand this entire manual before attempting to assemble operate or install the product NOTE Pumps with the UL Mark and pumps with the US mark are tested to UL Standard UL778 CSA certifie...

Страница 3: ...ls or with cisterns or lakes Description Quantity Pump 1 PREPARATION Before beginning installation of product make sure all parts are present If any part is missing or damaged do not attempt to assemb...

Страница 4: ...nufacturer Always glue in a vertical direction whenever possible to prevent glue from dripping inside pipe or fittings CAUTION Use pipe tape and pipe paste compound on all male threads Tighten with wr...

Страница 5: ...ssure gauge to ensure it s set to 18 PSI a Use a tire pump to adjust the PSI to 18 PSI b If water leaks from the air release valve replace the pressure tank CHECK TANK PRESSURE 20 20 20 20 Breaker Box...

Страница 6: ...come in contact with oil grease hot surfaces or chemicals The pump must be properly grounded using the proper wire cable with ground CAUTION Protect the power cable from coming in contact with sharp o...

Страница 7: ...of the pressure switch Wire from motor Wire from power supply 7 IL1376 Wire from motor Pressure switch Strain relief 6 6 Insert an electrical wire strain relief into the opening in the opposite side...

Страница 8: ...nomical to run and requires a smaller wire size NOTE This pump is pre wired at the factory to run on 115 V A B L1 L2 IL1356 230V GRAY RED 2b A B L1 L2 IL1355 GRAY RED 2a b Pull the red wire with the f...

Страница 9: ...eaker box and check all pipe connections for leaks All connections must be water and air tight in order for pump to operate All piping from the well to the pump should slope slightly upward with no sa...

Страница 10: ...has been determined Please review the following troubleshooting questions before returning a pump as defective If you have any questions please call Customer Service at 800 584 8089 MODEL LIQUID PUMP...

Страница 11: ...his warranty must be returned to the manufacturer at Kendallville Indiana or such other place as the manufacturer may designate freight prepaid THE WARRANTY PROVIDED HEREIN IS IN LIEU OF ALL OTHER EXP...

Отзывы: