6
7
IL1360
4
IL1359
Pump
Flow
Arrow
3b
IL1104
Water Level
25 ft.
Max
Suction
Lift
1 in.
Discharge Pipe
1-1/4 in.
Suction
Pipe
Discharge
to Home
Pipe
Support
Foot Valve
3a
IL1358
Glue
2
IL1357
Glue
1
3a. NOTE: For drilled (cased) wells, a foot
valve is required in the well at the end of
the pipe to maintain prime.
1. Make the connection to your well first. Wrap
all threaded fittings with pipe tape 5 times and
then apply a pipe paste (pipe dope) to ensure
an air tight connection.
CAUTION:
Dry-fit entire assembly to ensure proper fit before gluing or taping parts.
CAUTION:
Follow all proper gluing procedures as specified by the glue manufacturer. Always
glue in a vertical direction whenever possible to prevent glue from dripping inside pipe or fittings
CAUTION:
Use pipe tape and pipe paste compound on all male threads. Tighten with wrench to
a snug fit and add another 1/4 turn to ensure proper seal.
3b. For driven wells, a check valve is required
at the top of the well to maintain prime. Flow
arrow must point toward pump.
4. Finish the connection to your well with
additional pipe and fittings as needed.
WELL TO PUMP CONNECTION (SUCTION PIPE)
2. The use of a union (optional) will assist with
easy connection and disconnect.
1
IL1361
Tape
1. Begin the connection to the pressure tank.
Using a 1 in. x 3 in. galvanized nipple, wrap
the threads 5 times with pipe tape or apply
pipe paste (pipe dope) and install in top of
pump.
PUMP TO PRESSURE TANK CONNECTION (DISCHARGE PIPE)