2
3
Power supply required ...........................................................................115 volts or 230 volts, 60 Hz
(Pump is set by the factory to run on 115 volts)
Maximum water temperature ...........................................................................................77°F (25°C)
Individual branch circuit required ............................................................................15 Amp minimum
Discharge connection ..........................................................................................................1 in. NPT
Suction connection ........................................................................................................1-1/4 in. NPT
Motor duty..................... Continuous duty with enforced air cooling and thermal overload protection
Pressure switch ...........................................................................
Preset at 20 PSI “on” / 40 PSI “off”
Water depth rating ................................................................................................. Maximum of 25 ft.
ITEM #
HP
VOLTAGE HZ
MAX
AMPS
LOCKED
ROTOR
AMPS
CAPACITY - U.S. GALLONS PER MINUTE
AT 20 PSI DISCHARGE PRESSURE
0 FT.
5 FT.
15 FT.
25 FT.
1461-0006
3/4
115/230
60 13/6.5 36.0/18.0
15
10
9
5
• ELECTRICAL SHOCK HAZARD.
Always disconnect power source before performing any work on or near the motor or its
connected load. If the power disconnect point is out-of-sight, lock it in the open position and tag it
to prevent unexpected application of power. Failure to do so could result in fatal electrical shock.
• ELECTRICAL SHOCK HAZARD.
Do not handle the pump with wet hands or when standing in water as fatal electrical shock could
occur. Disconnect main power before handling unit for ANY REASON!
• RISK OF ELECTRIC SHOCK.
These pumps have not been investigated for use in swimming pool areas.
• ELECTRICAL SHOCK ALERT.
Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the
Occupational Safety and Health Act (OSHA).
• ELECTRICAL SHOCK ALERT.
Replace damaged or worn wiring cord immediately. Never use an extension cord.
• ELECTRICAL SHOCK ALERT.
Do not kink power cable and never allow the cable to come in contact with oil, grease, hot
surfaces, or chemicals.
SAFETY INFORMATION
Please read and understand this entire manual before attempting to assemble, operate, or install
the product.
• NOTE:
Pumps with the “UL” Mark and pumps with the “US” mark are tested to UL Standard
UL778. CSA certified pumps are certified to CSA Standard C22.2 No. 108. (CUS.)
DANGER
WARNING
PRODUCT SPECIFICATIONS
• ELECTRICAL SHOCK ALERT.
Wire motor to correct supply voltage. See motor nameplate and wiring diagrams and check
voltage of power supply.
• ELECTRICAL SHOCK ALERT.
Unit must be securely and adequately electrically grounded. This can be accomplished by wiring
the unit to a ground metal-clad raceway system or by using a separate ground wire connected to
the bare metal of the motor frame or other suitable means.
• ELECTRICAL SHOCK ALERT.
Make certain the electrical power source is adequate for the requirements of the pump.
• ELECTRICAL SHOCK ALERT.
Never use an extension cord with this pump.
• CHEMICAL ALERT.
Prop65 Warning for California residents:
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
• HAZARDOUS PRESSURE ALERT.
Install pressure relief valve in discharge pipe. Release all pressure on system before working on
any component.
• EXPLOSION ALERT
Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not
use in flammable and/or explosive atmospheres.
• PRODUCT DAMAGE MAY RESULT
This pump is not to be used for irrigation or water systems.
• PRODUCT DAMAGE MAY RESULT
Protect the power cable from coming in contact with sharp objects.
• PRODUCT DAMAGE MAY RESULT
Do not run pump dry.
• PRODUCT DAMAGE MAY RESULT
Pump and plumbing must be full of water before startup.
• PRODUCT DAMAGE MAY RESULT
Do not pump water which contains sand, mud, silt, or debris.
• INJURY MAY RESULT
Be careful when touching the exterior of an operating motor. It may be hot enough to be painful
or cause injury.
CAUTION