2.3.2 "Heating priority" option
• Before any work inside the appliance, you must cut the appliance’s electricity supply as there
is a risk of electric shock which may cause material damage, serious injury or even death.
• Use cables with a section of at least 2x0.75 mm², RO2V type and with a diameter between 8
and 13 mm.
This function allows the appliance to start or maintain filtration in order to detect the water temperature and thus activate
the filt heating unit to maintain a constant water temperature. The filter pump is thus said to be slaved to the
heating system. Filtration is kept in operation or activated if the pool temperature falls below the desired temperature
(see § “5.3 I Advanced setting parameters (accessible by a qualified technician)”).
The start-up of the pool's filtration pump also starts up the compressor. When the compressor stops, this also stops the
filtration pump.
The time between the compressor start-up and the pump start-up is configurable, just like the time between
the compressor stopping and the pump stopping.
• Connect as shown below.
Power for the filter pump
Two possible
connections for the
filter pump :
Two-pole
Three-pole
Heat pump
Filtration timer