11
2.3 I Electrical connections
2.3.1 Electrical power supply connection
• Before any work inside the appliance, you must cut the appliance’s electricity supply as there
is a risk of electric shock which may cause material damage, serious injury or even death.
• Incorrectly tightened terminals may cause the terminal box to heat up, which can invalidate
the warranty.
• Only a qualified and experienced technician is authorised to carry out cabling work within the
appliance or to replace the power cord.
• The installer must consult the electricity provider if necessary and ensure that the equipment
is connected correctly to an electricity network with impedance under 0.095 ohm.
•
The heat pump's electrical supply must be provided through a protection and circuit breaking device (not supplied)
complying with the standards and regulations in force in the country where it is installed.
•
The appliance is provided for connection to a general power supply with a TT or TN-S neutral regime.
•
Electrical protection: three-pole residual current circuit breaker (minimum 30 mA).
•
Additional protection may be required during installation to guarantee the overvoltage category II.
•
The power supply must correspond to the voltage indicated on the appliance's information plate.
•
If there are fluctuations in the input voltage, the installation of a voltage stabiliser is recommended to prevent damage
to the appliance.
•
The power cord must be insulated against any cutting or hot elements that may damage or crush it.
• The appliance must be connected to an earth socket.
•
The electrical connection lines must be fixed.
•
Use the gland to pass the power cord into the appliance.
•
Use the power cord (RO2V type) adapted for outdoor or buried use (or run the cable into a protection duct).
•
We recommend burying the cable at a depth of 50 cm (85 cm under a road or path) in an electrical duct.
•
If this buried cable meets another cable or pipe (gas, water, etc.), there must be more than 20 cm between them.
•
The electrical connection must be compliant with the wiring diagram (see §”5.5 I Wiring diagrams”)
•
Connect the power cord to the connection terminal board.
•
Connect the earth wire to the planned location.
•
The connections are shown in diagram form in the following image.
R - S - T
: Phases
N
: Neutral
EN
Содержание WH000456
Страница 2: ......