19
3.4.6 Setting parameters (user accessible)
The user can access the following parameters.
Code
Setting
Values
Factory settings
F11
Setpoint (in °C)
10 to 40
28
F50
Heating Priority
0: activated
1: deactivated
1
F58
Duration of audible alarm (in seconds)
0: alarm silent
0.1 - 10.0 (s)
606: until a key is pressed
0
F61
Calibration of the water inlet temperature
sensor (in °C)
-20 to 20
0
F62
Calibration of the water outlet
temperature sensor (in °C)
-20 to 20
0
F85
Display of the total operating time (in
days)
-
0
•
The qualified technician can access and modify the advanced settings with a password (see § “5.3 I
Advanced setting parameters (accessible by a qualified technician)”).
• Press
for about 3 seconds until a beep sound.
• Press
or
to select the setting to modify.
• Press
to select the setting and to adjust it.
• Press
or
to change the value.
• Press
to save the value.
• Press
to exit the settings menu.
EN