6
EN
•
Place the upper part of the POD Kit on the pipe, sliding it into the previously-drilled holes.
The arrows on the upper part of the POD collar show the directi on of water fl ow.
Adapter (labelled
“EU”) Ø50 mm
Collar Ø63
•
Click the 2 parts of the POD Kit collar together around the pipe. For a Ø50 mm pipe, use
the adapter labelled ‘EU’. Do not use this adapter for a Ø63 mm pipe.
•
Positi on the upper part of the POD Kit with its various components in the directi on
indicated by the foolproof locati ng notch, check that the point (
) of the clamping ring
and the arrow (
) of the clamp are aligned and ti ghten the locking ring fi rmly (hand-
ti ghten only).
pH sensor
Flow controller
Water circulati on directi on
pH minus injecti on
ACL sensor
A badly-installed sensor may give false readings and cause inappropriate operati on of the appliance. Neither the
manufacturer nor the unit shall be liable in this event.
Identi fy a suitable length (minimum 30 cm, without elbow) of
straight pipe.
•
Dismantle the POD Kit and keep the EU DN50 mm adapter
with 2 holes (
).
•
Turn the EU DN50 mm adapter and place it in the positi on
where you want to install it on the pipe.
•
Use a center-punch or marker pen to mark the positi on of
the holes to be made in the pipe (
).
•
Using the holes saw supplied, cut the 2 feed holes for the
POD Kit.
Ensure that the edges of the holes are smooth and deburred!