background image

1

WARNINGS

GENERAL WARNINGS

• 

Failure to respect the warnings may cause serious damage to the pool equipment or cause serious injury, even death.

• 

Only a person qualifi ed in the technical fi elds concerned (electricity, hydraulics or refrigerati on) is authorised to perform 

this procedure. The qualifi ed technician working on the appliance must use/wear personal protecti ve equipment (such as 

safety goggles and protecti ve gloves, etc.) in order to reduce the risk of injury occurring when working on the appliance.

• 

Before servicing the appliance, ensure that it is switched off  and isolated from the power supply circuit. 

• 

The appliance is intended to be used only for swimming pools and spas; it must not be used for any purpose other than 

that for which it has been designed.

• 

It is important that the appliance is operated by people who are competent and qualifi ed (both physically and mentally), 

aft er having read the instructi ons for use. Persons not meeti ng these criteria should not be allowed access to the appliance 

in order to prevent risk of property damage of injury, including loss of life.

• 

Keep the appliance out of the reach of children.

• 

The appliance must be installed according to the manufacturer’s instructi ons and in compliance with all applicable local 

and nati onal standards. The installer is responsible for installing the appliance and for compliance with nati onal installati on 

regulati ons. Under no circumstances may the manufacturer be held liable in the event of failure to comply with applicable 

local installati on standards.

• 

For any work other than the simple user maintenance described in this manual, the product should be referred to a quali-

fi ed professional.

• 

Incorrect installati on and/or use may cause serious damage to property or serious injuries (possibly causing death). 

• 

All equipment, even postage and packing paid, travels at the risks and perils of the recipient. The latt er shall issue reserves 

in writi ng on the carrier’s delivery slip if damage is detected, caused during transport (confi rmati on to be sent to the carrier 

within 48 hours by registered lett er). In the event that an appliance containing coolant has been turned on its side, menti on 

your reservati ons in writi ng to the carrier.

• 

If the appliance suff ers a malfuncti on, do not try to repair it yourself; instead contact a qualifi ed technician.

• 

Refer to the warranty conditi ons for details of the permitt ed water balance values for operati ng the appliance.

• 

In additi on to using spare parts manufactured by unauthorised third-party manufacturers, deacti vati ng, eliminati ng or by-

passing any of the safety mechanisms integral to the appliance, will automati cally void the warranty.

• 

Do not spray insecti cide or any other chemical (infl ammable or non-infl ammable) in the directi on of the appliance, as this 

may damage the body and cause a fi re.

• 

Zodiac® heat pump, fi ltrati on pump and fi lter appliances are compati ble with the most commonly used types of pool water 

treatment systems.

• 

Do not touch the fan and/or any moving parts and do not insert anything, including your fi ngers in the vicinity of the mov-

ing parts while the appliance is in operati on.

WARNINGS ASSOCIATED WITH ELECTRICAL APPLIANCES

• 

The electrical supply to the appliance must be protected by a dedicated 30 mA diff erenti al residual current protecti on de-

vice (RCD), complying with the standards and regulati ons in force in the country where it is installed.

• 

Do not use an extension cord to plug in the appliance; connect the appliance directly to a suitable power supply circuit.

• 

Before carrying out any operati ons, check that:

- The voltage indicated on the rati ng plate of the appliance corresponds to the mains voltage, 

- The power grid is adapted to the power requirements of the appliance, and is grounded. 

- The plug (where applicable) is suitable for the socket.

• 

In the event of abnormal functi on or signs of overheati ng such as a burning odour from the appliance, turn it of immedi-

ately, unplug / disconnect it from its power supply and contact a professional.

• 

Before accessing the enclosure for any reason, ensure that all power to the appliance and also power to any accessories or 

external devices which may be connected to the appliance, is disconnected from the mains power supply.

• 

Do not disconnect and reconnect the appliance to the power supply when in operati on.

• 

Do not pull on the power cord to disconnect it from the power supply.

• 

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in 

order to avoid a hazard.

• 

Do not att empt to carry out any servicing or maintenance operati ons with wet hands or while the appliance is wet.

• 

Ensure that all terminals for mains power are in good conditi on and free of corrosion and/or dirt/debris.

• 

For any component or sub-assembly containing a batt ery: do not recharge or dismantle the batt ery, or throw it into a fi re. 

Do not expose it to high temperatures or direct sunlight.

• 

In stormy weather, disconnect the appliance from the power supply to prevent it from suff ering lightning damage.

• 

Do not immerse the appliance in water (with the excepti on of cleaners) or mud.

Recycling

This symbol means that your appliance must not be thrown into a normal bin. It will be selecti vely collected for the 

purpose of reuse, recycling or transformati on. Any substances it may contain which are potenti ally dangerous to the 

environment shall be eliminated or neutralised.

Request informati on on recycling procedures from your retailer.

Содержание pH Link

Страница 1: ...H0493700 C 2018 02 More documents on www zodiac com Instructions for installation and use English pH regulation Redox regulation Translation of the original instructions in french EN...

Страница 2: ...automatically void the warranty Do not spray insecticide or any other chemical in ammable or non in ammable in the direction of the appliance as this may damage the body and cause a re Zodiac heat pum...

Страница 3: ...Installing the pH Link or Dual Link module 5 2 3 Installing the POD Kit 5 3 Use 8 3 1 Activating the module 8 3 2 Display 8 3 3 Calibrating the sensor s 9 3 4 Adjusting the set point s 10 3 5 Setting...

Страница 4: ...counterweight securing clip PTFE tape and stoppers suction injection hose 5 meters Buffer solution pH 7 5 Buffer solution 700 mV 1 2 Technical specifications pH Link module Dual Link module Supply vo...

Страница 5: ...essential that the pool water balance is controlled and adjusted before installing the appliance Making sure that the pool water balance is correct from the very start will reduce the likelihood of e...

Страница 6: ...sensor holding POD Kit and the pH minus injection pipe have been installed see 2 3 3 Installing the pH minus injection line 2 3 Installing the POD Kit The sensor holding POD Kit is a single assembly...

Страница 7: ...ligned and tighten the locking ring rmly hand tighten only pH sensor Flow controller Water circulation direction pH minus injection ACL sensor A badly installed sensor may give false readings and caus...

Страница 8: ...nstallation rinse the end of the sensor with tap water and shake off excess water For a restart after wintering clean the sensor see 4 1 Nettoyage de la des sonde s then calibrate it before installing...

Страница 9: ...made in the cap and put the ceramic counterweight and threaded locking nozzle on the end Ensure that ALL connections are correct and watertight before operating the pH Link or Dual Link module Replac...

Страница 10: ...sor into a sample of the 700 mV buffer solution supplied Leave the sensors immersed for about 1 minute to obtain a reliable measurement Press or the use the or keys to display CALIB PH or CALIB PH ACL...

Страница 11: ...e chlorine production potential decrease the ACL set point Dual Link module only We recommend that you check the free chlorine level in the pool a few days after the module is installed to determine i...

Страница 12: ...stopped immediately press or Con rm that the pump is primed pH minus solution will be visible in the translucent pipes To prime the peristaltic pump more quickly it may be necessary to repeat these st...

Страница 13: ...2 glass of water Always pour the hydrochloric acid into the water The reverse method can lead to acid projections Once cleaning is complete dispose of the solution according to the standards in e ect...

Страница 14: ...s Check the pH in the pool Calibrate or replace the pH sensor The pH minus container is empty Replace the container The peristaltic pump is not primed Test the peristaltic pump The pH sensor is dirty...

Страница 15: ...e sensor see 4 1 Cleaning the sensor s If the problem continues contact your reseller To cancel the PH ERROR and ACL ERROR messages press or for 3 or 4 seconds when the message appears The other codes...

Страница 16: ...erie BP 90023 49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number...