14
EN
Observati on
Causes
Soluti ons
ACL
VERY LOW
or
ACL BLOCKED
Water balance incorrect
Check the water balance parameters (see «2.1 Prepa-
ring the pool: water balance»)
Excess chlorine stabiliser
Parti ally drain the pool then top up with fresh water
(then check the salt rate).
The 700 mV buff er soluti on is no longer
eff ecti ve
Check that the 700 mV buff er soluti on’s manufac-
turing date is less than 2 years old, and is in good
conditi on.
The sensor needs cleaning
Clean the sensor (see «4.1 Cleaning the sensor(s)»)
If the problem conti nues contact your reseller
.
To cancel the "PH ERROR" and "ACL ERROR" messages, press
or
for 3 or 4 seconds when the
message appears.
The other codes are only informati on messages that disappear automati cally when the operati ng conditi ons
return to opti mal.
6. Product conformity
This appliance is intended to be installed exclusively on the Zodiac® electrolyser or hydroxinator.
This appliance has been designed and manufactured to be in conformity with the applicable requirements of the
following standards: EN 60335-1
Relative to which it is compliant. The product has been tested under the normal conditions of use.