background image

10

EN

3.4 Adjusting the set point(s)

The set point is displayed conti nuously on the LCD home screen.

The default setti  ng for the pH set point is pH7.2 (pH Link and Dual Link modules).

The default setti  ng for the ACL set point is 4 (Dual Link module). 

This value provides the ideal compromise to achieve opti mum effi  ciency in terms of water disinfecti on. 

• 

Calibrati ng the sensors (see “3.3 Calibrati ng the sensor(s)”).

• 

Press 

 or 

 the use the 

 or 

 keys to display "CALIB. PH" or "CALIB. PH\ACL", then press 

 or 

.

• 

Use the 

 or 

  keys to display 'PH SET POINT' or 'ACL SET POINT', then press 

 or 

.

• 

Use the  

 or 

  keys to change the set point value.

• 

Press 

 or 

 or wait 30 seconds to exit.

• 

The ACL set point displayed does not match the free chlorine concentrati on in the pool. This is the desired 

level of 'disinfecti on potenti al' in the water.

• 

The ACL set point required to reach the opti mum chlorine level is diff erent in every swimming pool. A period 

manual measurement of free chlorine level in the pool is therefore necessary to adjust this ACL set point.

• 

To increase the chlorine producti on potenti al: increase the ACL set point.

• 

To decrease the chlorine producti on potenti al: decrease the ACL set point.

Dual Link module only:

We recommend that you check the free chlorine level in the pool a few days aft er the module is installed to 

determine if the rate is ideal (0.5 to 2 ppm, see “2.1 Preparing the pool: water balance”). If, aft er this period, 

the free chlorine level is unsuitable, the ACL set point must be changed. 

3.5 Setting the pool volume

List of levels with corresponding volumes:

• 

Level 1: For small pools up to 40 m³

• 

Level 2: For mid-size pools from 40 to 60 m³ (default level)

• 

Level 3: For large pools between 60 and 110 m³

• 

Level 4: For very large pools over 110 m³

• 

These values are for guidance only; the choice may vary according to the conditi ons of use. 

• 

When the volume of the pool is at the limit between 2 levels, it is bett er to use the higher level. 

• 

However, we recommend not 'over-sizing' the choice of level, to avoid using too much pH minus.

• 

A dose of pH minus is injected into the pool every 2 hours (when the fi ltrati on and water treatment systems 

are running).

• 

Press 

 or 

 the use the 

 or 

 keys to display "CALIB. PH' or 'CALIB. PH\ACL", then press 

 or 

.

• 

Use the  

 or 

  keys to display 'POOL VOLUME', then press 

 or 

.

• 

Use the 

 or 

  keys to select the desired level appropriate to the pool size.

• 

Press 

 or 

 to confi rm the choice then press 

 or 

 or wait 30 seconds to exit.

Содержание pH Link

Страница 1: ...H0493700 C 2018 02 More documents on www zodiac com Instructions for installation and use English pH regulation Redox regulation Translation of the original instructions in french EN...

Страница 2: ...automatically void the warranty Do not spray insecticide or any other chemical in ammable or non in ammable in the direction of the appliance as this may damage the body and cause a re Zodiac heat pum...

Страница 3: ...Installing the pH Link or Dual Link module 5 2 3 Installing the POD Kit 5 3 Use 8 3 1 Activating the module 8 3 2 Display 8 3 3 Calibrating the sensor s 9 3 4 Adjusting the set point s 10 3 5 Setting...

Страница 4: ...counterweight securing clip PTFE tape and stoppers suction injection hose 5 meters Buffer solution pH 7 5 Buffer solution 700 mV 1 2 Technical specifications pH Link module Dual Link module Supply vo...

Страница 5: ...essential that the pool water balance is controlled and adjusted before installing the appliance Making sure that the pool water balance is correct from the very start will reduce the likelihood of e...

Страница 6: ...sensor holding POD Kit and the pH minus injection pipe have been installed see 2 3 3 Installing the pH minus injection line 2 3 Installing the POD Kit The sensor holding POD Kit is a single assembly...

Страница 7: ...ligned and tighten the locking ring rmly hand tighten only pH sensor Flow controller Water circulation direction pH minus injection ACL sensor A badly installed sensor may give false readings and caus...

Страница 8: ...nstallation rinse the end of the sensor with tap water and shake off excess water For a restart after wintering clean the sensor see 4 1 Nettoyage de la des sonde s then calibrate it before installing...

Страница 9: ...made in the cap and put the ceramic counterweight and threaded locking nozzle on the end Ensure that ALL connections are correct and watertight before operating the pH Link or Dual Link module Replac...

Страница 10: ...sor into a sample of the 700 mV buffer solution supplied Leave the sensors immersed for about 1 minute to obtain a reliable measurement Press or the use the or keys to display CALIB PH or CALIB PH ACL...

Страница 11: ...e chlorine production potential decrease the ACL set point Dual Link module only We recommend that you check the free chlorine level in the pool a few days after the module is installed to determine i...

Страница 12: ...stopped immediately press or Con rm that the pump is primed pH minus solution will be visible in the translucent pipes To prime the peristaltic pump more quickly it may be necessary to repeat these st...

Страница 13: ...2 glass of water Always pour the hydrochloric acid into the water The reverse method can lead to acid projections Once cleaning is complete dispose of the solution according to the standards in e ect...

Страница 14: ...s Check the pH in the pool Calibrate or replace the pH sensor The pH minus container is empty Replace the container The peristaltic pump is not primed Test the peristaltic pump The pH sensor is dirty...