3
1.1.3 Storage and transport conditions
1.1.4 Field of application
1.1.5 How it works
Temperatures for information
1.2 Technical characteristics
PF
Single phase
voltage
Power
consumed*
Power
restored*
Nominale
current
consumption* COP*
Sound
power*
Sound
pressure at
10 meters*
kW
kW
A
dBA
dBA
6M
230V-50Hz 1.3 6.4
6.25 4.7
65.3 37.3
8M
230V-50Hz
1.6
7.3
7.3
4.5
65.2
37.2
11M
230V-50Hz 2.2 10
10.5 4.6
66.7 38.7
13M
230V-50Hz
2.8
12.1
13
4.3
65.1
37.1
15M
230V-50Hz 3.1 14.5
15
4.7
65.1 37.1
*
with an ambient air of +15 °C and a pool water of 26 °C, humidity 70% (in compliance with the French
NF-414 standard)
unit protection class:
IP 24
refrigerant gas:
R410A
refrigerant charge: see product name plate
class : I,
degree of pollution : 2,
overvoltage category : II
1.3 Operating conditions
Operating range:
between 5 °C and 38 °C of air temperature
between 5 °C and 32 °C of water temperature
Maximum temperature limited at 32°C to protect the pool liner.
Exclusive use: heating swimming pool water
It must not be used for anything else.
The appliance must be transported upright on its pallet.
Air 15 °C
Water 28 °C
Water 26 °C
Air 10 °C
Evapo
rato
r
Con
den
se
r
Compressor
Expansion valve
EN
condenstates
Содержание PF 6M-8M-11M-13M-15M
Страница 17: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...
Страница 18: ...1 Electric diagram PF 6M 8M...